![ABB HART FEH300 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/abb/hart-feh300/hart-feh300_commissioning-instruction_4426021.webp)
Installation
CI/FEP300/FEH300-EN
ProcessMaster / HygienicMaster
EN - 19
3.5.5 Sensor
type
HygienicMaster
Ground the stainless steel model as shown in the figure. The measuring fluid is grounded via
the adapter (1) and an additional ground is not required.
Fig. 22
3.5.6 Ground for devices with hard rubber lining
For devices with meter sizes DN 100 and larger, the liner contains a conductive element. This
element grounds the measuring fluid.
3.5.7 Ground for devices with protective plates
The protective plates are used to protect the edges of the liner in the measuring tube, e.g., for
abrasive fluids. In addition, they function as a grounding plate.
•
For plastic or pipes with insulating lining, electrically connect the protective plate in the same
manner as a grounding plate.
3.5.8 Ground with conductive PTFE grounding plate
For devices with a meter size between DN 10 … 150, grounding plates made of conductive
PTFE are available. These are installed similar to conventional grounding plates.