![ABB HART FEH300 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/abb/hart-feh300/hart-feh300_commissioning-instruction_4426017.webp)
Installation
CI/FEP300/FEH300-EN
ProcessMaster / HygienicMaster
EN - 15
Change from one to two columns
3.4 Installation
Requirements
The device measures the flowrate in both directions. The factory
default is forward flow, as shown inFig. 8.
Fig. 8
The following items must be observed:
3.4.1 Electrode
axis
Electrode axis (1) should be horizontal if at all possible or no more
that 45° from horizontal.
G00041
max. 45°
1
Fig. 9
3.4.2 In- and outlet pipe sections
Straight inlet section
Straight outlet section
≥
3 x DN
≥
2 x DN
DN = Flowmeter sensor size
•
Do not install fittings, manifolds, valves etc. directly in front of the
meter tube (1).
•
Butterfly valves must be installed so that the valve plate does not
extend into the flowmeter sensor.
•
Valves or other turn-off components should be installed in the
outlet pipe section (2).
•
For compliance with the measuring accuracy, observe the inlet
and outlet pipe sections.
G00037
1
2
3xDN
2xDN
Fig. 10
3.4.3 Vertical
connections
•
Vertical installation for measurement of abrasive fluids, flow
preferably from below to above.
Fig. 11
3.4.4 Horizontal
connections
•
Meter tube must always be completely full.
•
Provide for a slight incline of the connection for degassing.
G00038
3°
Fig. 12
3.4.5 Free inlet or outlet
•
Do not install the flowmeter at the highest point or in the draining-
off side of the pipeline, flowmeter runs empty, air bubbles can
form (1).
•
Provide for a siphon fluid intake for free inlets or outlets so that
the pipeline is always full (2).
G00040
1
2
Fig. 13
3.4.6 Strongly contaminated fluids
•
For strongly contaminated fluids, a bypass connection according
to the figure is recommended so that operation of the system can
continue to run without interruption the during the mechanical
cleaning.
G00042
Fig. 14