5.3 Update revolution counters
Procedure
This procedure must be applied if revolution counter value is loss for the Track.
Note/Illustration
Action
xx1800002078
Align the sharp edge of the moving part of the
calibration marker with the line of the fixed part
calibration marker.
1
Tap
ABB
on the top left of the FlexPendant.
2
Tap
Calibration
.
3
Select the desired mechanical unit.
4
Tap
Update revolution counters
.
5
Select the desired axis.
6
Tap
Update
.
7
Product manual - FlexTrack IRT501-66/66R/90/90R
177
3HAW050008590-001 Revision: C