DIN
8 Templates and Functionality
IM/CM/I–EN Rev. P
81
8 Templates and Functionality
ControlMaster CM15 and CMF160 indicators fitted without a
software key have basic templates and functionality.
ControlMaster CM15 and CMF160 indicators fitted with 2
software keys have dual templates and functionality.
8.1 Basic Templates
8.1.1 Single Channel PV
This template enables the indication of a single PV.
8.1.2 One PV / Totalizer
This template enables a single PV along with totalization of
that PV, providing the ability to show either the Batch Total
(default) or Secure Total.
Note.
Input assignments can be changed in Device Setup
/ Custom Config – see page 36.
Output assignments can be changed in Input /
Output configuration – see page 44.
PV
AIN 1
PV
AIN 1
Batch Total
Secure Total
PV
Totalizer 1
(Analog)