- 24 -
010CC4
4 - CDD display operations
G
eneral Information
cyclical display
B
asic information menu
M
ain menu - Statistics
GENERAL INFORMATION cyclical display
Total output power
level of the MICRO Inverters that make up the plant
Total energy
produced by the plant from the time it is put into operation
Plant quality
expressed as a percentage and labeled Low, Medium, or High
MICRO: X
= number of inverters in the plant
EXTRA: Y
= number of inverters over limit of 30
Alarm status
displays presence or absence of alarms, see section 7 for alarm codes
Date and time
set on the CDD, use CHANGE SETTINGS menu to modify values
WLess
strength of network connection, represented by 1 to 4 symbols
Press any button while in the GENERAL INFORMATION display to view the BASIC
information described below. Use the UP and DOWN buttons to scroll through the list.
BASIC information and options
Web Server IP
address used to access the local web server of the CDD
MAC Addr. WLess
address relating to the CDD
Subnet Mask
address relating to internet
IP Gateway
address used to send data of the monitored plant
Primary DNS
primary address of internet domain name server
Secondary DNS
secondary address of internet domain name server
Wless Enabled, Yes >
wireless connectivity is enabled by default
Press ENTER to remove arrow >, press DOWN to scroll to NO, press
ENTER to select NO and disable wireless connectivity
Wless AutoConn., Yes >
auto connection to last network connected is
recommended and enabled by default; press ENTER to remove arrow >,
press DOWN to scroll to NO, press ENTER to select NO and disable
Web Server, Reset Password?
default password (admin) of the local web
server can be reset, press ENTER to reset
Wless SSID:
name of connected wireless network
To access the MAIN menus described below and continued on next page, press and hold
the UP and DOWN buttons until the Set Password screen appears; default password is 0010.
Scroll UP or DOWN to select a number and press ENTER to accept each digit.
MAIN menus
Statistics
of the system and each inverter
Tot output
power level of the inverters that make up the plant
Total
Energy
produced by the plant from the time it is put into operation
Inverter data >
press ENTER to view
# microinverter
displays the total number of inverters in the plant
SN xxxxxx >
lists each inverter by serial number; scroll DOWN list
of inverters, press ENTER to select inverter and view following data:
Total Energy
Input
Voltage
Output
Power
DSP
Release
Micro
Release
Model
ID
MAC
Address
Output
Current
Input
Current
Output
Voltage
Frequency
Temperature
View Information
read only display
Change Settings
modify CDD settings and acquire inverters
, ENTER to confirm