Dataq DI-4108 Скачать руководство пользователя страница 1

T h e   w a y   P C - b a s e d   i n s t r u m e n t a t i o n   s h o u l d   b e

DI-4108 and DI-4208

8-Channel High Speed Data Acquisition Systems with Programmable Gain,

Expandability with ChannelStretch™, and Stand-alone Capability

User's Manual

Manual Revision G

Copyright © 2020 by DATAQ Instruments, Inc. The Information contained herein is the exclusive property of 
DATAQ Instruments, Inc., except as otherwise indicated and shall not be reproduced, transmitted, transcribed, stored 
in a retrieval system, or translated into any human or computer language, in any form or by any means, electronic, 
mechanical, magnetic, optical, chemical, manual, or otherwise without expressed written authorization from the com-
pany. The distribution of this material outside the company may occur only as authorized by the company in writing.

DATAQ Instruments' hardware and software products are not designed to be used in the diagnosis and treatment of 
humans, nor are they to be used as critical components in any life-support systems whose failure to perform can rea-
sonably be expected to cause significant injury to humans.

DATAQ, the DATAQ logo, and W

IN

D

AQ

 are registered trademarks of DATAQ Instruments, Inc. All rights reserved.

DATAQ Instruments, Inc.

241 Springside Drive

Akron, Ohio 44333 U.S.A.

Telephone: 330-668-1444

Fax: 330-666-5434

Designed and manufactured in the

United States of America

Содержание DI-4108

Страница 1: ...c mechanical magnetic optical chemical manual or otherwise without expressed written authorization from the com pany The distribution of this material outside the company may occur only as authorized...

Страница 2: ......

Страница 3: ...products that have been repaired or altered by persons other than DATAQ Instru ments employees or products that have been subjected to misuse neglect improper installation or accident DATAQ Instrumen...

Страница 4: ......

Страница 5: ...Leads 11 Analog Inputs 11 Low pass Filter 13 Resolution as a Function of Sample Rate 13 Digital Ports 14 WinDaq Remote Events D0 Event 15 WinDaq Remote Storage D1 Record 17 WinDaq Rate D2 Rate 17 WinD...

Страница 6: ......

Страница 7: ...option allows the user to configure a recording session through their PC then record data in the field to removable flash memory via the USB drive port without being connected to their PC Stand alone...

Страница 8: ...your data and is available for free from our web site www dataq com WINDAQ Lite Data Acquisition software free can be used to record waveforms directly and continuously to disk while monitoring a real...

Страница 9: ...nel to channel crosstalk rejection 80 dB ADC Characteristics Resolution 12 to 16 bit Above zero ADC counts 2 047 to 32 767 Below zero ADC counts 2 048 to 32 768 Max throughput sample rate Standard 160...

Страница 10: ...erface USB 2 0 mini B style connector Button Multi function control Start Stop Save Configuration Apply Configu ration USB A Connector Drive USB drive for Stand alone data logging Cannot be used concu...

Страница 11: ...ments should be connected to the same Ethernet switch Power Power Consumption 1 0 Watt via USB interface Environmental Operating Temperature 0 C to 50 C 32 F to 122 F Operating Humidity 0 to 90 non co...

Страница 12: ......

Страница 13: ...u through the appropri ate steps for replacing missing or damaged items Save the original packing material in the unlikely event that your unit must for any reason be sent back to DATAQ Instruments In...

Страница 14: ...DI 4x08 The device MAC address is printed on the bottom label of the device 2 Login to your Router and ensure the DHCP server is enabled 3 Access the DHCP Reservations Static DHCP or IP Allocations p...

Страница 15: ...onnector pins or screws To avoid ESD damage in handling the device take the following precautions Ground yourself with a grounding strap or by touching a grounded object before and during your handlin...

Страница 16: ...ons Refer to the following for screw terminal port identification Ch Analog channels 1 8 Programmable 2 5 10 20 50 100 Volts 120 V rms max D Digital port 0 6 Can also be used for specific WINDAQ funct...

Страница 17: ...flap tightens only against the signal wire and not the wire insulation Do not over tighten 3 Tug gently on the signal lead to ensure that it is firmly secured When an input signal is connected and WI...

Страница 18: ...hannel in the menu item Edit Channel Settings Scroll through all enabled channels with the Next and Previous buttons DI 4108 Channel Settings DI 4208 Channel Settings Status D0 D1 D2 D3 D4 D5 D6 Model...

Страница 19: ...The DI 4108 and DI 4208 calculate its own Last Point Maximum Minimum and Filter data making it available at the programming level Acquisition methods RMS and Frequency are permanently disabled for th...

Страница 20: ...d 100 mA Many of the ports also provide specific func tionality in WINDAQ or a third party program D0 Event is for WINDAQ Remote Events This bit inserts an event marker in your data D1 Record is for W...

Страница 21: ...Acquisition Software Events may be automatically placed on the rising or falling edge of the trigger signal Use the menu command Options Remote Events to set WINDAQ to place event markers on low to hi...

Страница 22: ...nu command Options Remote Events or Options Remote Events An example event marker in a WINDAQ data file is shown below Please Note Event Markers do not display in the real time WINDAQ acquisition soft...

Страница 23: ...Use the menu command Options Remote Storage 1 to set WINDAQ to begin recording on low to high transitions of the Record input Use the menu command Options Remote Storage 0 to set WINDAQ to begin reco...

Страница 24: ...el 10 in the channel display then select Edit Channel Settings in the menu to specify a full scale range for the Rate channel Ranges of 10 20 50 100 200 500 1000 2000 5000 10000 20000 and 50000 Hz are...

Страница 25: ...r sec ond the measurement interval remains the same Tachometer measurements in units of RPM revolutions per min ute is just one example that benefits from selecting this option For example if the 100...

Страница 26: ...aximum count value is 65 535 before the counter resets to zero automatically Use the Edit Reset Count command in WINDAQ Acquisition software to reset counts immediately to zero This feature is availab...

Страница 27: ...Edit Channels in the WINDAQ Acquisition menu to open the Channel Selection grid Channel 9 is the designated Digital Input channel Click on the Channel 9 channel box to enable disable the digital inpu...

Страница 28: ...te and Count inputs if those channels are enabled With Channel 9 selected in the display window click Scaling Digital Plot to show a digital display and make the data more meaningful on screen General...

Страница 29: ...be placed on the low side of the circuit as shown below Status D0 D1 D2 D3 D4 D5 D6 Model DI 4108 or DI 4208 USB Button 5V GnD CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1 120 V rms 0 25V Max Count Rate Record Ev...

Страница 30: ...ided below for a more detailed description of each available state as well as a description of some states not displayed on the label Volt EU EU Tag Upper Level 5 20 mA Lower Level 1 4 State Mode Desc...

Страница 31: ...ption could result in data file cor ruption Blinking Blue Green Armed USB thumb Drive is waiting for a trig ger condition The device is acquiring data and waiting for a trigger condition to begin reco...

Страница 32: ...ect the device to your PC via the USB port 2 Apply power to the device 3 When mode LED stops blinking white and is in Idle mode push and hold the Control button This must be com pleted within five sec...

Страница 33: ...e Drive while holding the button in 5 Release the button when the mode LED changes to Red Black 6 The device will read and load the configuration files to the device and revert to Idle mode when compl...

Страница 34: ...DI 4718B U and the DI 4718B E can synchronize with other USB devices via the USB interface The DI 4718B E can also synchronize with other Ethernet instruments via the Ethernet interface Connect up to...

Страница 35: ...e absolutely sure you are on the same controller is to use a powered USB hub to PC to Power as required USB Hub or Ethernet Switch 16 units max 0D WKURXJKSXW N ChannelStretch Technology Status D1 D2 D...

Страница 36: ...ual Controls Indicators and Connections 30 Channel Selection Devices are listed in the Channel Selection grid in alpha numeric order of the serial numbers of the device Devices must be connected to th...

Страница 37: ...ducts di 4108 to purchase either unlock code or call 330 668 1444 Once purchased you will be given a Key code to enter into WinDaq for WinDaq Unlock or the WinDaq Dashboard for SA Enabled WinDaq Unloc...

Страница 38: ...8 Hardware Manual Unlock WinDaq 32 3 Click on the Yes button to enter your code Click on the No button to go to Stand alone configuration for a single channel 4 Enter the Key in the appropriate dialog...

Страница 39: ...DI 4108 and DI 4208 Hardware Manual Dimensional Drawing 33 6 Dimensional Drawing Top View Side View All dimensions in inches...

Страница 40: ......

Отзывы: