![ABB ACS850-04 series Скачать руководство пользователя страница 138](http://html.mh-extra.com/html/abb/acs850-04-series/acs850-04-series_hardware-manual_2582138.webp)
Technical data
138
UL marking
The drive is cULus listed.
UL checklist
• The drive is to be used in a heated, indoor controlled environment. The drive must
be installed in clean air according to enclosure classification. Cooling air must be
clean, free from corrosive materials and electrically conductive dust. See page
• The maximum ambient air temperature is 40 °C (104 °F) at rated current. The
current is derated for +40…55 °C (+104…131 °F).
• The drive is suitable for use in a circuit capable of delivering not more than
100,000 rms symmetrical amperes, 500 V maximum when the input cable is
protected with T-class fuses. The ampere rating is based on tests done according
to UL 508A.
• The cables located within the motor circuit must be rated for at least
75 °C (167 °F) in UL-compliant installations.
• The input cable must be protected with fuses. Circuit breakers must not be used
without fuses in the USA. For suitable circuit breakers, contact your local ABB
representative. Suitable IEC (class aR) fuses and UL (class J) fuses for drive
protection are listed on page
.
• For installation in Canada, branch circuit protection must be provided in
accordance with the Canadian Electrical Code and any applicable provincial
codes. To fulfil this requirement, use the UL classified fuses.
• For installation in the United States, branch circuit protection must be provided in
accordance with the National Electrical Code (NEC) and any applicable local
codes. To fulfill this requirement, use the UL classified fuses.
• The drive provides overload protection in accordance with the National Electrical
Code (NEC).
CSA marking
CSA marking is pending for the drive.
“C-tick” marking
A “C-tick” mark is attached to each drive in order to verify compliance with the EMC
product standard (EN 61800-3:2004), required under the Trans-Tasman
Electromagnetic Compatibility Scheme for levels 1, 2 and 3 in Australia and New
Zealand.
For fulfilling the requirements of the standard, see section
.
GOST R certificate of conformity
The drive has been given a GOST R certificate of conformity. Available on request.
Содержание ACS850-04 series
Страница 1: ...ABB machinery drives Hardware manual ACS850 04 drive modules 160 to 560 kW 200 to 700 hp ...
Страница 4: ......
Страница 12: ...Table of contents 12 ...
Страница 20: ...Safety instructions 20 ...
Страница 26: ...Introduction to the manual 26 ...
Страница 81: ...Installation 81 Assembly drawing frame G1 3AUA0000132078 ...
Страница 82: ...Installation 82 Assembly drawing frame G2 3AUA0000132062 ...
Страница 83: ...Installation 83 Assembly drawing air baffles 3AUA0000132062 ...
Страница 92: ...Installation 92 3 6a 6b 5 4 8 4 8 6a 6b 7a 7b 7b ...
Страница 93: ...Installation 93 Assembly drawing of installing the drive module to the cabinet frame G1 3AUA0000132078 ...
Страница 94: ...Installation 94 Assembly drawing of installing the drive module to the cabinet frame G2 3AUA0000132062 ...
Страница 98: ...Installation 98 3AUA0000038989 TXD transmitter RXD receiver JRIB V2 V1 V7 V6 1 2 APOW JINT 2 JRIB 1 4 3 JGDR ...
Страница 112: ...Installation checklist 112 ...
Страница 114: ...Start up 114 ...
Страница 116: ...Fault tracing 116 ...
Страница 140: ...Technical data 140 ...
Страница 142: ...Dimension drawings 142 Frame G1 Drive module dimensions ...
Страница 143: ...Dimension drawings 143 Frame G1 Drive module dimensions with optional cabling panels H381 ...
Страница 144: ...Dimension drawings 144 ...
Страница 145: ...Dimension drawings 145 Frame G1 Cabling panels H383 installed into a Rittal TS 8 cabinet ...
Страница 146: ...Dimension drawings 146 Frame G2 Drive module dimensions ...
Страница 147: ...Dimension drawings 147 Frame G2 Drive module dimensions with optional cabling panels H381 ...
Страница 148: ...Dimension drawings 148 ...
Страница 149: ...Dimension drawings 149 Frame G2 Cabling panels H383 installed into a Rittal TS 8 cabinet ...
Страница 150: ...Dimension drawings 150 Frames G1 and G2 Bottom plate 3AUA0000082240 ...
Страница 151: ...Dimension drawings 151 Frames G1 and G2 Air baffles 3AUA0000138986 ...
Страница 152: ...Dimension drawings 152 ...
Страница 162: ...du dt filters 162 ...
Страница 164: ...3AUA0000081249 Rev C EN 2013 04 11 Contact us www abb com drives www abb com drivespartners ...