![background image](http://html.mh-extra.com/html/abb/acs850-04-series/acs850-04-series_hardware-manual_2582133.webp)
Technical data
133
Isolation and grounding
diagram
Efficiency
Approximately 98% at nominal power level
Degree of protection
IP00 (UL type open). With H381: IP20 (UL type open).
Note:
The degree of protection of IP20 requires that the input power cables are installed
through the rubber grommet mounted on top of the module (+H381).
+24VI
GND
NO
COM
NC
1
2
1
2
3
NO
COM
NC
4
5
6
+24VD
DIGND
+24VD
1
2
3
DIOGND
4
DI1
DI2
XDI
1
2
DI3
3
DI4
4
DIIL
A
DIO1
DIO2
1
2
+VREF
-VREF
AGND
1
2
3
AI1+
4
AI1-
AI2+
5
6
AI2-
7
AO1+
AO1-
AO2+
1
2
3
AO2-
4
B
A
BGND
1
2
3
OUT1
OUT2
IN1
1
2
3
IN2
4
XPOW
XRO1 XRO3
XD24
XDIO
XAI
XAO
XD2D
XSTO
DI5
5
DI6
6
NO
COM
NC
7
8
9
Ground
Common mode voltage
between channels
± 20 V
Содержание ACS850-04 series
Страница 1: ...ABB machinery drives Hardware manual ACS850 04 drive modules 160 to 560 kW 200 to 700 hp ...
Страница 4: ......
Страница 12: ...Table of contents 12 ...
Страница 20: ...Safety instructions 20 ...
Страница 26: ...Introduction to the manual 26 ...
Страница 81: ...Installation 81 Assembly drawing frame G1 3AUA0000132078 ...
Страница 82: ...Installation 82 Assembly drawing frame G2 3AUA0000132062 ...
Страница 83: ...Installation 83 Assembly drawing air baffles 3AUA0000132062 ...
Страница 92: ...Installation 92 3 6a 6b 5 4 8 4 8 6a 6b 7a 7b 7b ...
Страница 93: ...Installation 93 Assembly drawing of installing the drive module to the cabinet frame G1 3AUA0000132078 ...
Страница 94: ...Installation 94 Assembly drawing of installing the drive module to the cabinet frame G2 3AUA0000132062 ...
Страница 98: ...Installation 98 3AUA0000038989 TXD transmitter RXD receiver JRIB V2 V1 V7 V6 1 2 APOW JINT 2 JRIB 1 4 3 JGDR ...
Страница 112: ...Installation checklist 112 ...
Страница 114: ...Start up 114 ...
Страница 116: ...Fault tracing 116 ...
Страница 140: ...Technical data 140 ...
Страница 142: ...Dimension drawings 142 Frame G1 Drive module dimensions ...
Страница 143: ...Dimension drawings 143 Frame G1 Drive module dimensions with optional cabling panels H381 ...
Страница 144: ...Dimension drawings 144 ...
Страница 145: ...Dimension drawings 145 Frame G1 Cabling panels H383 installed into a Rittal TS 8 cabinet ...
Страница 146: ...Dimension drawings 146 Frame G2 Drive module dimensions ...
Страница 147: ...Dimension drawings 147 Frame G2 Drive module dimensions with optional cabling panels H381 ...
Страница 148: ...Dimension drawings 148 ...
Страница 149: ...Dimension drawings 149 Frame G2 Cabling panels H383 installed into a Rittal TS 8 cabinet ...
Страница 150: ...Dimension drawings 150 Frames G1 and G2 Bottom plate 3AUA0000082240 ...
Страница 151: ...Dimension drawings 151 Frames G1 and G2 Air baffles 3AUA0000138986 ...
Страница 152: ...Dimension drawings 152 ...
Страница 162: ...du dt filters 162 ...
Страница 164: ...3AUA0000081249 Rev C EN 2013 04 11 Contact us www abb com drives www abb com drivespartners ...