Appendix A – ACS/ACC/ACP 601 Technical Data
A-2
ACx=ACS/ACC/ACP
ACS/ACC/ACP 601 Drives
Rating table continued
Pump and Fan Use
(Squared Load)
ACx 601
Type
I
2Nsq
[A]
S
N
[kVA]
P
N
[kW]
P
N
[HP]
Frame
SIze
Three-phase supply voltage 380 V, 400 V or 415 V
ACx 601-0005-3
7.6
5
3
3
R2
ACx 601-0006-3
11
6
4
5
ACx 601-0009-3
15
9
5.5
7.5
ACx 601-0011-3
18
11
7.5
10
R3
ACx 601-0016-3
24
16
11
15
ACx 601-0021-3
41
20
15
20
R4
ACx 601-0026-3
47
25
18.5
25
ACx 601-0031-3
62
30
22
30
R5
ACx 601-0041-3
76
40
30
40
ACx 601-0051-3
89
50
37
50
ACx 601-0061-3
112
60
45
60
R6
ACx 601-0071-3
124
70
55
75
ACx 601-0101-3
178
100
75
100
R7
ACx 601-0121-3
200
120
90
125
Three-phase supply voltage 380 V, 400 V, 415 V, 440
V, 460 V, 480 V or 500 V
ACx 601-0006-5
7.6
6
4
5
R2
ACx 601-0009-5
11
9
5.5
7.5
ACx 601-0011-5
15
11
7.5
10
ACx 601-0016-5
18
16
11
10
R3
ACx 601-0020-5
24
20
15
15
ACx 601-0026-5
41
25
18.5
20
R4
ACx 601-0031-5
47
30
22
30
ACx 601-0041-5
58
40
30
30
R5
ACx 601-0051-5
65
50
37
40
ACx 601-0061-5
84
60
45
50
ACx 601-0071-5
112
70
55
60
R6
ACx 601-0101-5
124
100
75
75
ACx 601-0121-5
164
120
90
100
R7
ACx 601-0141-5
200
140
110
125
Normal use (10 % overload capacity):
Heavy-duty use (50 % or 100 % overload capacity):
I
2N
rated RMS output current
I
2hd
rated RMS output current
I
2Nmax
short term rms overload current (allowed
for one minute every 10 minutes).
I
2hdmax
rms overload current (allowed for one
minute every 10 minutes or 2 seconds
every 15 seconds) Maximum current
depends on parameter setting, refer to
Firmware Manual.
S
N
rated apparent output power
S
hd
rated apparent output power
P
N
typical motor power. The power ratings in
kW apply to most IEC 34 motors. The
power ratings in HP apply to most four pole
NEMA rated motors.
P
hd
typical motor power. The power ratings in
kW apply to most IEC 34 motors. The
power ratings in HP apply to most four pole
NEMA rated motors..
Pump and Fan use (squared load): no overload capacity
I
2Nsq
rated RMS output current
S
N
rated apparent output power
P
N
typical motor power. The power ratings in
kW apply to most IEC 34 motors. The
power ratings in HP apply to most four pole
NEMA rated motors.
Current ratings are for drives in IP 20/21
enclosures. For drives in IP 54 enclosures,
see page A-4. For output current
temperature derating, see page A-3.
The current ratings are the same regardless
of the supply voltage within one voltage
range. The rated current of the ACx 60x
must be higher than or equal to the rated
motor current to achieve the rated motor
power given in the table
.
Note 1: The maximum allowed motor shaft
power is limited to 1.5 · P
hd
. If the limit is
exceeded, the motor torque and the I
hdmax
2 s current is automatically restricted. The
function protects the input bridge of the
ACS 600 against overload.
Note 2: The load capacity (current and
power) decreases if the installation site
altitude exceeds 1000 meters (3300 ft.), or
if the ambient temperature exceeds 40 °C
(104 °F(35 °C/95 °F for ACx 601-0120-03
units).
Note 3: The Pump and Fan rating is not to
be used with du/dt filters.
Usually dv/dt filters are needed at the
output of 525 V to 690 V units with random
wound motors. No dv/dt filters are usually
required with form wound motors.
Содержание ACS 601
Страница 4: ......
Страница 6: ......
Страница 14: ...Safety Instructions x ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Страница 18: ...xiv ACx ACS ACC ACP ACS ACC ACP Drives ...
Страница 22: ...Chapter 1 Introduction 1 4 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Страница 26: ...Chapter 2 Mechanical Installation 2 4 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Страница 40: ...Chapter 3 Electrical Installation 3 14 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Страница 42: ...Chapter 4 Installation Checklist 4 2 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Страница 44: ...Chapter 5 Maintenance 5 2 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Страница 82: ...Appendix B ACS ACC ACP 601 Dimensional Drawings B 14 ACx ACS ACC ACP ACS ACC ACP 601 Drives ...
Страница 87: ......