62
ACS 400 User’s Manual
Application Macro Premagnetize
This macro is intended for those applications where the drive must start very quickly. Building up
the flux in the motor always takes time. With the Premagnetize Macro, this delay can be eliminated.
The value of parameter 9902 is 7 (
PREMAGN
).
*Constant speed selection: 0 = open, 1 = connected
Premagnetise parameter values:
Input signals
Output signals
Jumper Setting
• Start, stop and direction
(DI1,2)
• An. output AO: Frequency
• Analog reference (AI1)
• Relay output 1: Fault
• Preset speed selection (DI3,4)
• Relay output 2: Running
• Premagnetize (DI5)
DI3
DI4
Output
0
0
Reference through AI1
1
0
Constant speed 1 (1202)
0
1
Constant speed 2 (1203)
1
1
Constant speed 3 (1204)
1001
EXT
1
COMMANDS
2 (
DI
1,2)
1402
RELAY
OUTPUT
2
2 (
RUN
)
1002
EXT
2
COMMANDS
0 (
NOT
SEL
)
1503
AO
CONTENT
MAX
60 Hz
1003
DIRECTION
3 (
REQUEST
)
1601
RUN
ENABLE
0 (
NOT
SEL
)
1102
EXT
1/
EXT
2
SEL
6 (
EXT
1)
1604
FAULT
RESET
SEL
0 (
KEYPAD
)
1103
EXT
REF
1
SELECT
1 (
AI
1)
2008
MAXIMUM
FREQ
60 Hz
1105
EXT
REF
1
MAX
60 Hz
2105
PREMAGN
SEL
5 (DI5)
1106
EXT
REF
2
SELECT
0 (
KEYPAD
)
2201
ACC
/
DEC
1/2
SEL
0 (
NOT
SEL
)
1201
CONST
SPEED
SEL
7 (
DI
3,4)
4001
PID
GAIN
1.0
1401
RELAY
OUTPUT
1
3 (
FAULT
(-1))
4002
PID
INTEG
TIME
60 s
External Reference 1: 0...10 V <=> 0...50 Hz
Reference voltage 10 VDC
Not used
Output frequency 0...20 mA <=> 0...50 Hz
+24 VDC
Start/Stop: Active to start ACS 400
Fwd/Rev: Activate to reverse rotation
Constant Speed selection*
Constant Speed selection*
Premagnetise: Activate to start premagnetising
Relay output 1, programmable
Default operation: Fault => 17 connected to 18
Relay output 2, programmable
Default operation: Running => 20 connected to 22
http://nicontrols.com
Содержание ACS 400
Страница 3: ...http nicontrols com ...
Страница 5: ...http nicontrols com ...
Страница 7: ...iv ACS 400 User s Manual http nicontrols com ...
Страница 45: ...34 ACS 400 User s Manual http nicontrols com ...
Страница 52: ...ACS 400 User s Manual 41 Motor Will Not Run http nicontrols com ...
Страница 53: ...42 ACS 400 User s Manual Motor Stalls during Acceleration http nicontrols com ...
Страница 54: ...ACS 400 User s Manual 43 Overvoltage Fault Indication http nicontrols com ...
Страница 55: ...44 ACS 400 User s Manual Overcurrent Fault Indication http nicontrols com ...
Страница 56: ...ACS 400 User s Manual 45 Overload Fault Indication http nicontrols com ...
Страница 57: ...46 ACS 400 User s Manual Undervoltage Fault Indication http nicontrols com ...
Страница 58: ...ACS 400 User s Manual 47 External Fault Indication http nicontrols com ...
Страница 59: ...48 ACS 400 User s Manual No Operator Display http nicontrols com ...
Страница 75: ...64 ACS 400 User s Manual http nicontrols com ...
Страница 161: ...150 ACS 400 User s Manual http nicontrols com ...
Страница 167: ...156 ACS 400 User s Manual http nicontrols com ...
Страница 177: ...166 ACS 400 User s Manual http nicontrols com ...
Страница 179: ...168 ACS 400 User s Manual ACS 400 NEMA Type 1 Enclosure R2 Frame Size http nicontrols com ...
Страница 180: ...ACS 400 User s Manual 169 ACS 400 NEMA Type 1 Enclosure R3 Frame Size http nicontrols com ...
Страница 181: ...170 ACS 400 User s Manual ACS 400 NEMA Type 1 Enclosure R4 Frame Size http nicontrols com ...
Страница 182: ...ACS 400 User s Manual 171 ACS 400 NEMA Type 12 4 Enclosure R1 Frame Size http nicontrols com ...
Страница 183: ...172 ACS 400 User s Manual ACS 400 NEMA 12 4 Enclosure R2 Frame Size http nicontrols com ...
Страница 184: ...ACS 400 User s Manual 173 ACS 400 NEMA Type 12 4 R3 Frame Size http nicontrols com ...
Страница 185: ...174 ACS 400 User s Manual ACS 400 NEMA Type 12 4 R4 Frame Size http nicontrols com ...
Страница 186: ...http nicontrols com ...