94
ACS 400 User’s Manual
Group 30: Fault Functions
ACS 400 can be configured to respond as desired to certain abnormal external conditions: analog
input fault, external fault signal and panel loss.
In these cases, the drive can either continue operation at current speed or at a set constant speed
while showing an alarm, ignore the condition, or trip on a fault and stop.
Motor thermal protection parameters 3004 - 3008 provide a means of adjusting the motor load
curve. For example, limiting the load near zero speed might be necessary if the motor does not
have a cooling fan.
Stall protection (parameters 3009 - 3012) includes parameters for stall frequency, stall time and
current.
Code Description
3001
AI<MIN FUNCTION
Operation in case of AI signal drops below fault limit 3022
AI
1
FLT
LIMIT
or 3023
AI
2
FLT
LIMIT
.
0 =
NOT
SEL
No operation.
1 =
FAULT
A fault indication is displayed and the ACS 400 coasts to stop.
2 =
CONST
SP
7
A warning indication is displayed and the speed is set according to parameter 1208
CONST
SPEED
7.
3 =
LAST
SPEED
A warning indication is displayed and the speed is set to the level at which the ACS 400 was last operating.
This value is determined by the average speed over the last 10 seconds.
Caution: If you select
CONST
SPEED
7 or
LAST
SPEED
, make sure that it is safe to continue operation in case
the analog input signal is lost.
3002
PANEL LOSS
Operation in case of control panel loss fault.
1 =
FAULT
A fault indication is displayed and the ACS 400 coasts to stop.
2 =
CONST
SP
7
A warning indication is displayed and the speed is set according to parameter 1208
CONST
SPEED
7.
3 =
LAST
SPEED
A warning indication is displayed and the speed is set to the level at which the ACS 400 was last operating.
This value is determined by the average speed over the last 10 seconds.
Caution: If you select
CONST
SPEED
7 or
LAST
SPEED
, make sure that it is safe to continue operation in case
the panel is lost.
3003
EXTERNAL FAULT
External fault input selection.
0 =
NOT
SEL
External fault signal is not used.
1...5 =
DI
1...
DI
5
This selection defines the digital input used for an external fault signal. If an external fault occurs, i.e. digital
input is deactivated, the ACS 400 is stopped and the motor coasts to stop and fault indication is displayed.
http://nicontrols.com
Содержание ACS 400
Страница 3: ...http nicontrols com ...
Страница 5: ...http nicontrols com ...
Страница 7: ...iv ACS 400 User s Manual http nicontrols com ...
Страница 45: ...34 ACS 400 User s Manual http nicontrols com ...
Страница 52: ...ACS 400 User s Manual 41 Motor Will Not Run http nicontrols com ...
Страница 53: ...42 ACS 400 User s Manual Motor Stalls during Acceleration http nicontrols com ...
Страница 54: ...ACS 400 User s Manual 43 Overvoltage Fault Indication http nicontrols com ...
Страница 55: ...44 ACS 400 User s Manual Overcurrent Fault Indication http nicontrols com ...
Страница 56: ...ACS 400 User s Manual 45 Overload Fault Indication http nicontrols com ...
Страница 57: ...46 ACS 400 User s Manual Undervoltage Fault Indication http nicontrols com ...
Страница 58: ...ACS 400 User s Manual 47 External Fault Indication http nicontrols com ...
Страница 59: ...48 ACS 400 User s Manual No Operator Display http nicontrols com ...
Страница 75: ...64 ACS 400 User s Manual http nicontrols com ...
Страница 161: ...150 ACS 400 User s Manual http nicontrols com ...
Страница 167: ...156 ACS 400 User s Manual http nicontrols com ...
Страница 177: ...166 ACS 400 User s Manual http nicontrols com ...
Страница 179: ...168 ACS 400 User s Manual ACS 400 NEMA Type 1 Enclosure R2 Frame Size http nicontrols com ...
Страница 180: ...ACS 400 User s Manual 169 ACS 400 NEMA Type 1 Enclosure R3 Frame Size http nicontrols com ...
Страница 181: ...170 ACS 400 User s Manual ACS 400 NEMA Type 1 Enclosure R4 Frame Size http nicontrols com ...
Страница 182: ...ACS 400 User s Manual 171 ACS 400 NEMA Type 12 4 Enclosure R1 Frame Size http nicontrols com ...
Страница 183: ...172 ACS 400 User s Manual ACS 400 NEMA 12 4 Enclosure R2 Frame Size http nicontrols com ...
Страница 184: ...ACS 400 User s Manual 173 ACS 400 NEMA Type 12 4 R3 Frame Size http nicontrols com ...
Страница 185: ...174 ACS 400 User s Manual ACS 400 NEMA Type 12 4 R4 Frame Size http nicontrols com ...
Страница 186: ...http nicontrols com ...