![ABB ACH550-01 Скачать руководство пользователя страница 371](http://html.mh-extra.com/html/abb/ach550-01/ach550-01_user-manual_2924371.webp)
Diagnostics and maintenance
359
ACH550 User's Manual
History
For reference, the last three fault codes are stored into
parameters 0401, 0412 and 0413. For the most recent fault
(identified by parameter 0401), the drive stores additional data
(in parameters 0402…0411) to aid in troubleshooting a problem.
For example, parameter 0404 stores the motor speed at the time
of the fault.
To clear the fault history (all of
parameters), follow these steps:
1.
In the control panel, Parameters mode, select parameter
0401.
2.
Press EDIT.
3.
Press the UP and DOWN keys simultaneously.
4.
Press SAVE.
Correcting alarms
The recommended corrective action for alarms is:
• Determine if the alarm requires any corrective action (action
is not always required).
• Use
below to find and address the root cause of
the problem.
Alarm listing
The following table lists the alarms by code number and
describes each.
Alarm
code
Display
Description
2001
OVERCURRENT
The current limiting controller is active. Check for
and correct:
• excessive motor load
• insufficient acceleration time (parameters 2202
ACCELER
TIME
1 and 2205
ACCELER
TIME
2)
• faulty motor, motor cables or connections.
2002
OVERVOLTAGE
The overvoltage controller is active. Check for and
correct:
• static or transient overvoltages in the input
power supply
• insufficient deceleration time (parameters 2203
DECELER
TIME
1 and 2206
DECELER
TIME
2).
Содержание ACH550-01
Страница 1: ...ACH550 User s Manual ACH550 01 Drives 0 75 110 kW ACH550 UH Drives 1 150 HP ABB ...
Страница 10: ...Update Notice 8 ...
Страница 12: ......
Страница 18: ...6 ACH550 User s Manual ...
Страница 50: ...38 Preparing for installation ACH550 User s Manual ...
Страница 325: ...313 ACH550 User s Manual ...
Страница 358: ...346 ACH550 User s Manual ...
Страница 409: ...Technical data 397 ACH550 User s Manual Frame size R1 IP54 UL Type 12 ...
Страница 410: ...398 Technical data ACH550 User s Manual Frame size R2 IP54 UL Type 12 ...
Страница 411: ...Technical data 399 ACH550 User s Manual Frame size R3 IP54 UL Type 12 ...
Страница 412: ...400 Technical data ACH550 User s Manual Frame size R4 IP54 UL Type 12 ...
Страница 413: ...Technical data 401 ACH550 User s Manual Frame size R5 IP54 UL Type 12 ...
Страница 414: ...402 Technical data ACH550 User s Manual Frame size R6 IP54 UL Type 12 ...
Страница 415: ...Technical data 403 ACH550 User s Manual Frame size R1 IP21 UL Type 1 ...
Страница 416: ...404 Technical data ACH550 User s Manual Frame size R2 IP21 UL Type 1 ...
Страница 417: ...Technical data 405 ACH550 User s Manual Frame size R3 IP21 UL Type 1 ...
Страница 418: ...406 Technical data ACH550 User s Manual Frame size R4 IP21 UL Type 1 ...
Страница 419: ...Technical data 407 ACH550 User s Manual Frame size R5 IP21 UL Type 1 ...
Страница 420: ...408 Technical data ACH550 User s Manual Frame size R6 IP21 UL Type 1 ...
Страница 453: ......