AMT/PTD/TR/0020/2/7/EN
10/2008
Page 4-94
An LD4 card or LD4NX card without ADPCM16 daughter card can be fitted in slots 00 to 13.
An LD4NX card in LD4X mode with ADPCM16 daughter card can be fitted in slots 00 to 13
without restriction.
An LD4N/LD4NX card (in LD4N mode) with ADPCM16 daughter card can be fitted in slots 6 and
7 without restriction. It is not allowed in slots 08 to 13.
When an LD4/LD4NX + ADPCM16 card is fitted in slot 00, no card on the short list may be fitted
in slot 08; when an LD4/LD4NX + ADPCM16 card is fitted in slot 01, no card on the short list
may be fitted in slot 09; when an LD4/LD4NX + ADPCM16 card is fitted in slot 02, no card on the
short list may be fitted in slot 10; when an LD4/LD4NX + ADPCM16 card is fitted in slot 03, no
card on the short list may be fitted in slot 11; when an LD4/LD4NX + ADPCM16 card is fitted in
slot 04, no card on the short list may be fitted in slot 12; when an LD4/LD4NX + ADPCM16 card
is fitted in slot 05, no card on the short list may be fitted in slot 13.
Short list: LA8, LN8, LM8, LH8, LI1, LR4, CP1, PT2 8 channels, PT2 16 channels, LD4, LD4NX,
MUM, IUMS.
Note:
Synchronising positions are positions 00 to 05. H0 in position 00 has priority over H1,
H2, H3, H4 and H5 which have the same priority.
Layout in a NeXspan S (main cabinet only)
Figure 4-11: Slot numbers on the backplane of an XS switch
An LD4/LD4NX card with or without ADPCM16 daughter card can be fitted in slots 00, 01 and
02.
Note:
The three slots are synchronising positions. H0 in position 00 has priority over H1, H2
and H3 (retrieved from the T0 interfaces built into the UCT-S card) which have the same
priority.
Installation in a NeXspan S12 (no expansion cabinet)
•
Non-rackable NeXspan S12: by default no expansion card (optional backplane)
•
Rackable NeXspan S12: 3 slots numbered 00 to 02.
Figure 4-12: Slot numbers on the backplane of an XS12
An LD4/LD4NX card with or without ADPCM16 daughter card can be fitted in slots 00, 01 and
02.
Note:
On an XS12 PBX, the back plane does not send network synchronisation (synchronising
positions are the T0 interfaces integrated into UCT). Therefore, the XS12 PBX cannot
receive LT2, LD4, LD4NX type synchronising cards with the T0 function.
02
01
00
UCT-S
02
01
00
UCT3S-12
Содержание X Series
Страница 3: ......
Страница 11: ...Page 1 11 10 2008 AMT PTD TR 0020 2 7 FR...
Страница 63: ...Page 2 63 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 73: ...Page 3 73 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 77: ...Page 4 77 10 2008 AMT PTD TR 0020 2 7 EN Figure 4 2 Top view of the LD4 ST card...
Страница 103: ...Page 4 103 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 105: ...Page 5 105 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 129: ...Page 6 129 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 171: ...Page 8 171 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 209: ...Page 12 209 10 2008 AMT PTD TR 0020 2 7 EN...