Page 4-79
10/2008
AMT/PTD/TR/0020/2/7/EN
4.3.2 Description of the switches
CA1.1
to
CA1.4
: these switches are used to adapt lines (factory setting, leave set to ON).
CA2
(located on the copper side): configure according to the card's location and mode (master/
slave).
For LD4 ST in T0
Case of LD4 ST in S0 configuration (for DECT base station)
Table2: Description of switches CA2.1 and CA2.2 on the LD4 ST card
SW1
: factory reserved; leave in position 1-2.
SW3
,
SW4
,
SW5
, and
SW6
: these jumper switches are used to disable each interface's remote
power supply when a T0 interface is connected.
Table3: Description of switches SW3 to SW6 on the LD4 ST card
SW7
and
SW8
: these jumper switches are used to set either a 40 V or 48 V remote power supply
Note:
The
power supply units of the NeXspan range do not supply ISDN 40 V. To supply 40 V
to sets and/or base stations, connect an external power supply unit to the J2 connector
on the LD4
ST
card.
CA2.1
(VALH)
Function
ON
Leave set to ON position. If the LD4 ST card is fitted in a synchronising slot, the ON
position allows the PBX to take the ISDN network clock as reference clock. In a non-
synchronising slot, CA2.1 has no effect. The synchronising positions in an XL cabinet
are the locations 1-00 to 1-05. For an XS cabinet, all positions are synchronising.
OFF
Do not set it to OFF position (in OFF position, the ISDN clock is not taken as reference,
whatever the slots).
CA2.2 (M/S)
Function
M
Master LD4 ST:
position not allowed
E
To be set in position E on all LD4 ST cards
SW3
Remote power supply for
interface 3
SW4
Remote power supply for
interface 2
SW5
Remote power supply for
interface 1
SW6
Remote power supply for
interface 0
SW7 and
SW8
Positions
Function
1-2
Selects the 48 V power supply
40
48
3
2
1
3
2
1
Содержание X Series
Страница 3: ......
Страница 11: ...Page 1 11 10 2008 AMT PTD TR 0020 2 7 FR...
Страница 63: ...Page 2 63 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 73: ...Page 3 73 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 77: ...Page 4 77 10 2008 AMT PTD TR 0020 2 7 EN Figure 4 2 Top view of the LD4 ST card...
Страница 103: ...Page 4 103 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 105: ...Page 5 105 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 129: ...Page 6 129 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 171: ...Page 8 171 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 209: ...Page 12 209 10 2008 AMT PTD TR 0020 2 7 EN...