AMT/PTD/TR/0020/2/7/EN
10/2008
Page 8-154
Indicators
There are several LEDs on the front panel of UCT cards providing information about
synchronisation clock operation and DECT multi-site synchronisation:
Note:
"S.DECT" and "MST DECT" LEDs are not available on the front panel of UCT-S12 and
UCT-C cards.
Note:
For NeXspan D, "S.DECT" and "MST DECT" LEDs are available on the IUCT-D card
front panel.
Table7: Meaning of UCT/IUCT-D card synchronisation LEDs
•
Operation in Simplex mode
1
Normal operation: the master is synchronised on the network (S.EXT, S.DECT and
MST.DECT LEDs lit). The slaves receive the DECT synchronisation signal from the master
(S.DECT LED lit green).
2
Break in the cable between the master and the first slave: the slave detects a malfunction
(S.DECT LED lit red); after a few moments the slave becomes master and generates its own
synchronisation to the other slaves (S.DECT and MST DECT LEDs lit).
•
Operation in Duplex mode
1
Normal operation: it is assumed that the two masters, "priority" and "not priority", are
connected to the PSTN network. The priority master supplies the entire multi-site network
with the synchronisation single (S.EXT, S.DECT and MST.DECT LEDs lit). The "not priority"
master and the slaves receive the DECT synchronisation signal from the priority master
(S.DECT and S.EXT LEDs lit on the not priority master, and S.DECT LED lit green on the
slaves).
2
The link between the "priority" master and the PSTN is broken (S.EXT LED out). This
information is sent (see wiring in section 8.4.3) to the "not priority" master. The "not priority"
master takes over, becomes master and supplies the synchronisation signal (S.EXT,
S.DECT and MST.DECT LEDs lit) to the entire network (S.DECT LED lit green on "priority"
master and slaves).
INDICATOR
STATE
EXPLANATION
S.EXT
(green/red)
ON green
Off
Network synchronisation clock correct
Synchronisation clock fault alarm
S.DECT
(green/red)
ON green
ON red
Flashes green
Flashes red
DECT synchronisation correct
DECT synchronisation loss alarm
Synchronisation search
Polarity inversion in the wiring of the DECT synchro signal
MST DECT
(green)
On
Synchronisation master PBX
Содержание X Series
Страница 3: ......
Страница 11: ...Page 1 11 10 2008 AMT PTD TR 0020 2 7 FR...
Страница 63: ...Page 2 63 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 73: ...Page 3 73 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 77: ...Page 4 77 10 2008 AMT PTD TR 0020 2 7 EN Figure 4 2 Top view of the LD4 ST card...
Страница 103: ...Page 4 103 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 105: ...Page 5 105 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 129: ...Page 6 129 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 171: ...Page 8 171 10 2008 AMT PTD TR 0020 2 7 EN...
Страница 209: ...Page 12 209 10 2008 AMT PTD TR 0020 2 7 EN...