 40 

KF format 

5if type 2 

 

This is the Karl-Fischer moisture meter format and is used when the peripheral equipment can only 
communicate using this format. 

  This format consists of fourteen characters excluding the terminator. 

  This format has no header characters. 

  The polarity sign is placed before the data, with spaces in place of leading zeros, if the data is 

not zero or overloaded.   

  This format outputs the unit only for a stable value. 

 

   

 

 

 

MT format 

5if type 3

 

  A header of two characters indicates the balance condition. 

  The polarity sign is used only for negative data.   

  The weighing data uses spaces in place of the leading zeros.   

  The character length of this format changes dependent upon the unit 

 

 

 

 

 

 

 

NU (Numerical) format  

5if type 4

 

This format outputs only numerical data. 

  This format consists of nine or ten characters excluding the terminator. 

With the MC-1000, when the numerical data excluding the decimal point exceeds eight 
characters, the data format will be ten characters long. 

  The polarity sign is placed before the data with the leading zeros. If the data is zero, the plus 

sign is used.   

 

(Data example exceeding 8 characters) 

 
 
 
 
 
 
 

+ 1 0 0 0 . 0 0 0 0   g

CR LF

Data

Unit

Terminator

S

    1 0 0 0 . 0 0 0 0   g

CR LF

Header

Unit Terminator

Data

+ 0 0 0 . 0 1 2 7

CR LF

Data

Terminator

+ 1 0 0 0 . 0 0 0 0

CR LF

Data

Terminator

g

Stable value

Unstable value

Содержание MC-1000

Страница 1: ...MC 1000 MC 6100 1WMPD4002204B...

Страница 2: ...ations and this manual are subject to change without any obligation on the part of the manufacturer Under the copyright laws the software program described in it are copyrighted with all rights reserv...

Страница 3: ...ghing 18 Adapting to the Environment 7 RESPONSE ADJUSTMENT SELF CHECK FUNCTION 20 7 1 Automatic Response Adjustment Self Check Function 20 7 2 Manual Response Adjustment 21 8 CALIBRATION 22 8 1 Calibr...

Страница 4: ...rface 12 RS 232C SERIAL INTERFACE EXTERNAL INPUT 47 13 CONNECTION TO PERIPHERAL EQUIPMENT 49 13 1 Connection to the AD 8121B Printer 49 13 2 Connection to a Computer 50 13 3 Using Windows Communicatio...

Страница 5: ...balance operation Adapting to the environment Describes response adjustment calibration and calibration test Functions Describes various functions of the balance RS 232C serial interface Describes th...

Страница 6: ...to take at his own expense whatever measures are necessary to eliminate the interference FCC Federal Communications Commission in the U S A Compliance With Directives of CE mark This device features...

Страница 7: ...5...

Страница 8: ...hat everything is included 2 1 MC 1000 Note Please confirm that the AC adapter type is correct for your local voltage and receptacle type Display Bubble spirit level Keys Reference card Dust guard Wei...

Страница 9: ...o secure the dust guard The dust guard securing screws and breeze break securing screws are different in length 1 Remove the weighing pan pan support receptors and dust guard from your balance To remo...

Страница 10: ...AX MC1000PAN breeze break using the provided securing screws At this time make sure to place the side of the breeze break with the screws at the back Attach the pan support receptors to the shock abs...

Страница 11: ...ubble spirit level Keys Reference card Dust guard Weighing pan Leveling foot RS 232C serial interface External input terminal Grounding terminal AC adapter jack AC adapter Main unit cover Main unit Ma...

Страница 12: ...ure the dust guard The dust guard securing screws and breeze break securing screws are different in length 1 Remove the weighing pan breeze ring pan support receptors and dust guard from your balance...

Страница 13: ...s at the back In addition place the breeze break toward the back of the balance as much as possible to prevent the breeze break from touching the auto centering pan guide Attach the pan support recept...

Страница 14: ...f the installation site During calibration using an internal mass it resolves up to one digit lower than the minimum weighing value Therefore be sure to place the balance in a stable environment The b...

Страница 15: ...stic sample with the wet cloth This balance uses a strong magnet as part of the balance assembly so please use caution when weighing magnetic materials such as iron If there is a problem use the under...

Страница 16: ...mass is in motion for example right after the AC adapter is connected or during calibration using the internal mass If the AC adapter is removed under the conditions described above the internal mass...

Страница 17: ...response adjustment and self check Performs calibration of the balance using the internal mass Displays calibration related menu Stores the weighing data in memory or outputs to a printer or personal...

Страница 18: ...he factory For details about the units and modes see the table below Name unit mode Abbrev Display Function table Storing mode Conversion factor 1 g Gram g 1 g Counting mode PC Percent mode Pct Ounce...

Страница 19: ...ight 707 dwt 1100 g 0 0001 Grain UK 16975 GN 1100 g 0 002 Tael HK general Singapore 19 8 TL 750 g 0 000005 Tael HK jewelry 19 7 TL 740 g 0 000005 Tael Taiwan 19 7 TL 740 g 0 000005 Tael China 19 2 TL...

Страница 20: ...1 Used When using as a mass comparator To avoid eccentric loading errors place the sample in the center of the weighing pan As an option auto centering pans are available AX MC1000PAN for the MC 1000...

Страница 21: ...the previous weight value is displayed upon power on For details refer to Zero upon power on on page 37 There is a function available to perform span calibration only when performing calibration with...

Страница 22: ...ay ba5fnc in the function table For details to 10 FUNCTION TABLE If the weight value is not stabilized due to drafts or vibration when Cond 0 is selected by the automatic response adjustment change th...

Страница 23: ...the response adjustment Operation 1 Press and hold the MODE key until RESPONSE is displayed then release the key Press the MODE key again quickly 2 Press the MODE key to select a rate of the response...

Страница 24: ...ta for GLP using the RS 232C interface set GLP output info of Data output dout For details refer to 10 FUNCTION TABLE Time and date are added to the GLP report If the time or date is not correct adjus...

Страница 25: ...blinks But it is recommended that to maintain the accuracy stop using the balance and confirm that there is nothing on the pan and allow the balance to perform self calibration 8 3 Calibration Using t...

Страница 26: ...tion weight value as follows SAMPLE key To switch between the calibration weight selection mode All of the digits blinking and the value adjustment mode The selected digits blinking With the MC 1000 t...

Страница 27: ...fo parameter of the function table is set to 1 or 2 the balance displays glp and outputs the Calibration Report using the RS 232C interface or stores the data in memory For details on the calibration...

Страница 28: ...the target weight value stored in the balance proceed to Step 5 4 Specify the target weight value as follows SAMPLE key To switch between the target weight selection mode All of the digits blinking an...

Страница 29: ...y The balance measures the target weight and displays the measured value Do not allow vibration or drafts to affect the balance 7 The balance displays end Remove the weight from the pan 8 The balance...

Страница 30: ...Correction range MC 1000 500 000 g 0 020 g MC 6100 2000 00 g 0 20 g Example Using the MC 6100 Operation 1 Calibrate the balance using the internal mass one touch calibration Then place an external wei...

Страница 31: ...ss value 9 Correct the internal mass value using the following keys RE ZERO key To select the value 20 digits appear after 20 digits PRINT key To store the new value and display the next menu of the f...

Страница 32: ...rations Switches Operation 1 Press the ON OFF key to turn off the display 2 While pressing and holding the PRINT key and the SAMPLE key press the ON OFF key The balance displays p5 3 Press the PRINT k...

Страница 33: ...alue Function switch settings Note Be sure to calibrate the balance after initialization Operation 1 Press the ON OFF key to turn off the display 2 While pressing and holding the PRINT key and the SAM...

Страница 34: ...symbol indicates that the parameter displayed is in effect When pressed and held in the weighing mode enters the function table mode Selects the class or item in the function table mode Changes the p...

Страница 35: ...Maximum capacity 100 0 Not used f1l Filter 1 Used when the balance is used as a mass comparator 0 Sets the display to zero p tr Zero upon power on 1 Does not set the display to zero Displays the prev...

Страница 36: ...to print difference 2 1000 digits Difference between reference value and displayed value 0 Not used 1 Stores unit mass in counting mode 2 Stores weighing data data Data memory 3 Stores calibration dat...

Страница 37: ...standard format 1 DP format 2 KF format 3 MT format 4 NU format type Data format 5 CSV format Refer to the GX series instruction manual 10 6 Description of the Item Data Format 0 No limit t Up Timeou...

Страница 38: ...8 6 4 seconds 0 1 2 3 4 5 f2 b Averaging range for the second moving average 6 Small Large 0 No averaging 1 0 5 second 2 1 0 second 3 1 5 seconds 4 2 0 seconds 5 2 5 seconds erfnc Extended function On...

Страница 39: ...nfluences the Auto print mode 5t b 0 This parameter is for sensitive response of the stabilization indicator Used for exact weighing 5t b 2 This parameter ignores slight fluctuation of a weight value...

Страница 40: ...e is added or removed with ar d set to 1 to adjust zero after the data is output Required setting dout prt 1 Auto print mode A reference zero dout ap p Auto print polarity dout ap b Auto print differe...

Страница 41: ...he data format will be sixteen characters long A header of two characters indicates the balance condition The polarity sign is placed before the data with the leading zeros If the data is zero the plu...

Страница 42: ...a The weighing data uses spaces in place of the leading zeros The character length of this format changes dependent upon the unit NU Numerical format 5if type 4 This format outputs only numerical data...

Страница 43: ...number dout d no 1 This format outputs the data number just before the data is transmitted using the RS 232C interface This format consists of six characters excluding the terminator When CSV format 5...

Страница 44: ...2 0 0 1 8 3 9 6 1 8 3 9 6 S D CR LF O L 9 9 9 9 9 9 E 1 9 9 9 9 9 9 9 9 9 9 S I E LF CR S I 9 9 9 9 9 9 9 9 CR LF O L 9 9 9 9 9 9 E 1 9 9 CR LF S T 0 0 0 0 1 7 2 g CR LF E Unit A D NU CR LF U S 1 2 1...

Страница 45: ...calibration test using an external weight Title block and End block for the weighing data Calibration and calibration test data can be stored in memory to output several reports at the same time Refer...

Страница 46: ...correct time and date in Clock Cl adj of the function table Calibration report using the internal mass When the setting is info 1 When the setting is info 2 A D TERM MODEL MC 1000 TERM S N 01234567 T...

Страница 47: ...el Serial number ID number Date Time Calibration type Calibration weight Signature TERM CR LF CR Space ASCII 20h Terminator or Carriage return ASCII 0Dh Line feed ASCII 0Ah CR LF A D TERM MODEL MC 100...

Страница 48: ...tting is info 1 When the setting is info 2 A D TERM MODEL MC 1000 TERM S N 01234567 TERM ID ABCDEFG TERM DATE TERM 2009 12 31 TERM START TERM TIME TERM 09 30 00 TERM TERM WT 1234 5600g TERM WT 1234 61...

Страница 49: ...bits Parity Even Odd Data bits 7 bits None Data bits 8 bits Stop bit 1 bit Code ASCII Pin connections Pin No Signal name Direction Description 1 FG Frame ground 2 RXD Input Receive data 3 TXD Output T...

Страница 50: ...he same operation as performed by pressing the PRINT key or the RE ZERO key will be performed Option Connector AX HDB 25P CTF Foot switch AX SW128 Balance side DCE Computer side DTE Inside of balance...

Страница 51: ...when the data output mode is set to the auto print mode prt 1 or prt 2 2 When multiple lines are to be printed set the parameter to 1 AD 8121B settings Mode AD 8121B DIP switches Description Mode 1 Pr...

Страница 52: ...e Can display or store the data using a text file format Can also print the data using a printer connected to the personal computer When several ports of a personal computer have balances connected th...

Страница 53: ...can be obtained 5 Using the MC series balance memory function The weighing data instead of outputting it immediately to an external device can be stored in the balance s memory Later all of the weigh...

Страница 54: ...tion set the Input method Cpin parameter to 0 or 1 Commands to control the memory function MCL Deletes all data in memory MD nnn Deletes weighing data with the data number nnn MA Outputs all data in m...

Страница 55: ...cess it the balance transmits the acknowledge code Among commands to control the balance the following transmit the acknowledge code both when the balance receives the command and when the balance has...

Страница 56: ...e is kept Hi normally When the balance can not receive the next command e g while the balance is processing last command the balance sets the CTS line to Lo The balance confirms the level of the RTS l...

Страница 57: ...Refer to Averaging range f1 b and averaging time f1 t 0 No averaging 1 0 5 second 2 1 0 second 3 1 5 seconds 4 2 0 seconds 5 2 5 seconds 6 3 2 seconds 7 4 8 seconds f1 t Averaging time for the first...

Страница 58: ...ht value 3 The process of averaging increases When the selected time is reached moving averaging will be performed When a small amount of sample is weighed or is filled the fluctuation of a weight val...

Страница 59: ...response is slow during full and medium flow Decrease the averaging range for the first moving average parameter f1 b Weaken the digital filter Decrease the function setting Condition Cond parameter...

Страница 60: ...tomatic Response Adjustment Self Check Function An error display appears when a malfunction is found Check the balance repeatability using an external weight Be sure to place the weight in the center...

Страница 61: ...lectricity and magnetic fields Refer to 3 PRECAUTIONS for details on the operating environment and 7 RESPONSE ADJUSTMENT about adapting the balance to the environment To return to the weighing mode pr...

Страница 62: ...counting be sure to add samples Automatic response adjustment zero error The automatic response adjustment can not be performed because there is something on the pan Clear the pan Press the CAL key to...

Страница 63: ...erent For details refer to the GX series instruction manual 12 DATA MEMORY EC E00 Communications error A protocol error occurred in communications Confirm the format baud rate and parity EC E01 Undefi...

Страница 64: ...this indicator blinks automatic self calibration is required The indicator blinks when the balance detects changes in ambient temperature If the balance is not used for several minutes with this indi...

Страница 65: ...ard RS 232C External calibration weight 1000 g 900 g 800 g 700 g 600 g 500 g 400 g 300 g 200 g 6000 g 5000 g 4000 g 3000 g 2000 g Weighing pan 128 x 128 mm 165 x 165 mm Net weight Approx 4 6 kg Approx...

Страница 66: ...ions of the environment where the balance is installed Being compact in size can be carried to the balance installation site easily One analyzer can manage several balances AD 1687 Weighing environmen...

Страница 67: ...the USB converter to the balance AD 1683 DC static eliminator A compact design with efficient static elimination No air blowing from a fan allows precision weighing AD 1684A Electrostatic field meter...

Страница 68: ...66 20 EXTERNAL DIMENSIONS MC 1000 MC 6100 Unit mm...

Страница 69: ...he balance a unit of minimum weighing value Tare To cancel the weight of a container which is not included in the weighing data Mode Balance operational function Re zero To set the display to zero GLP...

Страница 70: ...8 11 Auto display OFF 33 Auto display ON 33 Auto print mode A 34 38 Auto print mode B 34 38 Automatic Response Adjustment 20 Automatic Self Calibration 23 Averaging range 55 56 Averaging time 55 56 AX...

Страница 71: ...it 30 Initializing the balance 31 insulators 13 int 34 Interval memory mode 39 K Key mode 38 KF format 40 L Leveling foot 6 9 Linearity 58 63 M Main unit cover 6 9 Mmass comparator 3 8 11 18 33 Memory...

Страница 72: ...ibration weight 65 U Underhook 13 Unit 35 Units 16 USB converter 65 W Weighing capacity 13 60 63 Weighing environment analyzer 64 Weighing environment logger 64 Weighing pan 6 9 63 WinCT 6 9 50 Z Zero...

Страница 73: ...71 MEMO...

Страница 74: ...72 MEMO...

Страница 75: ...13...

Страница 76: ...50420 Fax 44 1235 550485 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D KOREA Limited 6 33 817 150 749 817 Manhattan Bld...

Страница 77: ...eter Description Cond Condition 2 Slow response rate stable value SLOW Bba5fnc Environment Display fil Filter 1 Used Note When the balance initialization is performed the function settings will be cha...

Отзывы: