![A&D AD-4212A Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/aandd/ad-4212a/ad-4212a_instruction-manual_446302046.webp)
44
10-10 Comparator Function
The balance outputs the results of the comparison in three or five levels.
AD-4212A series balance: 3-level output (standard) or 5-level output when OP-04 is installed.
AD-4212B series balance: 3-level or 5-level output, switched by “Comparator output setting
(
Cp-t
)” of the function table.
The comparison results are indicated by HI OK LO on the display and are contact-output from the I/O unit.
The following five comparison conditions are available by “Comparator mode (
Cp
)” of the function
table
Cp fnc
.
No comparison
Comparison when the weight value is stable or overloaded, excluding “near zero”
Comparison when the weight value is stable or overloaded, including “near zero”
Continuous comparison, excluding “near zero”
Continuous comparison, including “near zero”
Note
“Near zero” indicates the amount of ten digits (digit = the minimum displayable weighing value).
The comparison is performed using the upper limit value and lower limit value.
The function table
Cp fnc
has one more item: “Buzzer (
bep
)” to select whether or not to sound the
buzzer depending on the results.
Three-level comparison results
Three-level comparison
Comparison results
Display
Contact output
Buzzer
H I
OK
LO
H I
H I illuminated
short
open
open
OK
OK illuminated
open
short
open
LO
LO illuminated
open
open
short
Five-level comparison results
Lower limit value
H I
(upper limit value<weight value)
OK
(lower limit value
≦
weight value
≦
upper limit value)
LO
( weight value<lower limit value)
Weighing data
Upper limit value
Upper limit value
H H
(secondary upper limit value<weight value )
OK
(
lower limit value
≦
weight value
≦
upper limit value )
LO
(secondary lower limit value
≦
weight value<lower limit value )
Weighing data
Secondary upper limit value
LL
( weight value<secondary lower limit value )
H I
( upper limit value<weight value
≦
secondary
upper limit value)
Lower limit value
Secondary lower limit value