32
PulsePak Prime
GDED-IOM-216-B
Procedure:
1.
Ensure that protective personal equipment (PPE) is worn, which may
include protective clothing, breathing masks or breathing apparatus, head,
hand, eye and ear protection, approved footwear.
2.
Ensure that a sufficient quantity of polythene sacks is available at the
cartridge access door level.
3.
Turn off the compressed air and run the pulsing sequence allowing time
for the compressed air in the manifold to be fully exhausted.
4.
Lift the red handles on the access door covers and swing open the doors
on their hinges.
Door mechanism fully engaged.
5.
Slide the used cartridges out of the collector and dispose of in polythene
sacks.
6.
Clean the access doors internally and wipe clean the door gaskets.
Inspect the door gaskets for damage. Replace any worn gaskets. Inspect the
back wall to ensure no dust build up. Clean if necessary.