13
9. Indicator of hot water amount
10. Reset
Electric Leakage Inspection
Remote Controller
(Fig. 18)
Fig. 18
8. Instant Heating
When power on, users could touch to turn on “Instant heating” with flashes for three
times. Once reach setting temp, the heater will automatically change back to the mode before
“Instant heating”.
When “Instant heating” mode is on, users could touch to turn off “Instant heating” with
flashes just for one time.
Five blocks of light indicates the hot water amount available in tank. Based on your setting
temp,red blocks mean more hot water available than orange ones, which in turn mean more
hot water available than green ones.
Reset may help heater recover from misoperation or fault. Press and hold both and
simultaneously for 8 seconds, will turn off the heater after 2 seconds display off all characters on
screen, and reset setting temp, clock, timer to default status and remove AES memory.
In case of any unsafety detected, tri-polar power-off protection system will cut off power connec-
tion, with “reset” button popup and power indicator turned from green into orange.Please try to
push reset button, if it does not work, contact local authorized dealer.
Notice:
User should check the tri-polar power-off protection system regularly as follow: With power
indicator initially in green, press “Test” button to turn it off, and press “reset” button to turn it
back to green. Otherwise, contact local authorized dealer.
The function and operation of button on remote controller are similar
with the ones on electronic controller on theheater.
Install battery before use remote controller. (Refer to ChapterInstalla-
tion Instructions)
Please change battery if indicator dose not flash when press any button.
Using remote controller toward the receiver on water heater, and keep
distance within 4 meters.
z
z
z
z
Safety Valve Inspection
Safety valve is a kind of protection device against overpressure, thus it is a normal phenomenon
to see water discharged from safety valve when water pressure rises over 0.8Mpa due to heating
or supply reason.
NOTICE: User should check safety valve regularly as follow: open handle on safety valve to get rid
of the calcium carbonate deposit and etc., if water dose not discharge from valve, please contact
local authorized dealer.