vent attenuatIon asseMBlY

InstallatIon  InstructIons

The  Vent Attenuation Assembly  (VAA)  is  designed  to  provide  a 

reduction in fan noise created in the blower wheel. This installation 

of this VAA is optional. Review directions thoroughly prior to installing 

the new VAA. Please contact the manufacturer of the water heater as 

shown in the instruction manual with any questions or for additional 

product support.

vent attenuatIon asseMBlY KIt parts lIst

The kit consists of the following items. If a part is missing, use the 

contact  information  in  the  instruction  manual  to  acquire  missing 

component(s).

• vent attenuation assembly

• flexible tubing

• instruction sheet

vent attenuatIon asseMBlY InstallatIon

The  VAA  is  designed  for  both  vertical  and  horizontal  installations. 

The  vertical  installation  and  horizontal  installations  will  require  that 

the flexible condensate hose to be attached to the condensate hose 

barb located on the bottom of the VAA to release condensate. See 

instructions and diagrams that follow for a more detailed description.

Breathing Hazard - Carbon Monoxide Gas

• 

Do NOT block the holes in the hex plug of vent pipe 

  assembly #1.

• 

Do NOT elevate any portion of the field supplied drain 

  line beyond the 1/2" adaptor above the adaptor. This 

  must be true for entire length of the drain line including 

  the exit into an appropriate drain.

• 

Condensate lines must be free and clear of debris and 

 

must not allow back flow through drain line. Condensate 

 

lines must be able to flow freely to an appropriate drain.

• 

Do not allow condensate lines to become crimped closed.

• 

Analyze entire vent system to make sure that condensate

  will not become trapped in a section of vent pipe and 

  therefore reduce open cross sectional area of vent.

Breathing carbon monoxide can cause brain damage or death.

Always read and understand instruction manual.

Vertical VAA Installations (Recommended)

1.  The  VAA  is  designed  to  accept  two  inch  PVC  pipe  into  

the adapters on both ends. The VAA must be installed with the 

condensate hose barb pointing downward. See Figure 22. The 

VAA has an embossed flow arrow to reflect proper orientation. 

For optimum performance, install VAA as close as possible to  

the blower assembly.

2.  Use standard PVC cement (not included with kit) and glue the two 

inch PVC pipe coming from the blower into the VAA.

3.  Perform the same sequence on the PVC pipe coming from the 

exhaust side (vent terminal side) of the VAA.

4.  Make sure the VAA and vent pipe is supported securely to 

a  permanent  fixture  (stud  or  wall).  Use  standard  support 

straps  (not  supplied  with  kit)  that  may  be  found  at  a  local 

hardware store. Failure to properly support the VAA and the 

surrounding vent pipe could create a hazardous situation. DO 

NOT puncture any surface of the VAA.

5.  Locate flexible tubing. Slide one end of tubing over the hose 

barb located near end of the VAA. The ridges on the hose 

barb  should  prevent  the  tubing  from  sliding  off,  however, 

to ensure there are no leaks and possible dislocation from 

hose barb, use a wire tie or hose clamp (not supplied with kit) 

 

and secure.

6.  Take the other end of the flexible  tubing and slide it through 

the hose clamp on the jacket top cover and install it into one 

of the four barb fittings in vent pipe assembly #2.

7.  Once installed along with the rest of the vent configuration, 

make sure to operate the unit through at least one heat up 

cycle to ensure there is no leakage around the hose barb or 

any joints of the VAA or vent pipe system.

fIGure 22: typical vertical Installation

horizontal vaa Installations

1.  The VAA is designed to accept two inch PVC pipe into the 

adapters on both ends. The VAA must be installed with the 

condensate hose barb pointing downward. See Figure 23. The 

VAA has an embossed flow arrow to reflect proper orientation. 

For optimum performance, install VAA as close as possible 

to the blower assembly.

2.  Use standard PVC cement (not included with kit) and glue the 

two inch PVC pipe coming from the blower into the VAA.

3.  Perform the same sequence on the PVC pipe coming from the 

exhaust side (vent terminal side) of the VAA.

4.  Make sure the VAA and vent pipe is supported securely to a 

permanent fixture (stud or wall). Use standard support straps 

(not supplied with kit) that may be found at a local hardware 

store. Failure to properly support the VAA and the surrounding 

vent pipe could create a hazardous situation. DO NOT puncture 

any surface of theVAA.

5.  Locate flexible tubing. Slide one end of tube over the hose 

barb located near end of the VAA. The ridges on the hose 

barb  should  prevent  the  tube  from  sliding  off,  however,  to 

ensure there are no leaks and possible dislocation from hose 

Содержание GPHE 50 Series

Страница 1: ...DEALER FROM WHOM THE WATER HEATER WAS PURCHASED IF YOU ARE UNSUCCESSFUL PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER RESIDENTIAL GAS WATER HEATERS For Your Safety AN ODO...

Страница 2: ...alert symbol indicates a potentially hazardous situation which if not avoided could result in property damage WARNING CAUTION CAUTION DANGER All safety messages will generally tell you about the type...

Страница 3: ...3 GENERAL SAFETY INFORMATION...

Страница 4: ...4 GENERAL SAFETY INFORMATION at least 18 45 7cm above the floor This will reduce but not eliminate the risk...

Страница 5: ...tion Association 1 Batterymarch Park Quincy MA 02269 3 The water heater when installed must be grounded in accordance with the local codes or in the absence of local codes the National Electrical Code...

Страница 6: ...feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch...

Страница 7: ...ting 4 Places Shown DD Plastic Top EE On Off Switch FF Exhaust Tee GG Elbow GET TO KNOW YOUR WATER HEATER GAS MODELS A Vent Pipe B Anode C Hot Water Outlet D Outlet 120 VAC F Gas Supply G Main Manual...

Страница 8: ...8 TYPICAL INSTALLATION CONDENSATE HOSE AND DRAIN PAN FIGURE 1A...

Страница 9: ...time to burn relationship for normal adult skin If anyone using hot water provided by the water heater being installed fits into one of these groups or if there is a local code or state law requiring...

Страница 10: ...talled Water heaters are sometimes installed in locations where leakage may result in property damage even with the use of a drain pan piped to a drain However unanticipated damage can be reduced or p...

Страница 11: ...rine based chemicals refrigerants etc in addition to being highly flammable in many cases will also react to form corrosive hydrochloric acid when exposed to the combustion products of the water heate...

Страница 12: ...size of openings providing fresh air into confined spaces EXHAUST FANS Where exhaust fans are installed additional air should be provided to replace the exhausted air When an exhaust fan is installed...

Страница 13: ...a reference for the openings that provide fresh air into confined spaces only Do not refer to these illustrations for the purpose of vent installation See Installation of Vent System on pages 18 27 fo...

Страница 14: ...e requirements or such conditions as high line pressure among others have installed devices such as pressure reducing valves check valves and back flow preventers Devices such as these cause the water...

Страница 15: ...n 6 Spread the slit open and slip the insulation over the cold water inlet pipe Apply gentle pressure along the length of the insulation to ensure that it is fully seated around the pipe Also ensure t...

Страница 16: ...xcessive temperatures and pressures in the storage tank The T P valve is not intended for the constant relief of thermal expansion Aproperly sized thermal expansion tank must be installed on all close...

Страница 17: ...losing its individual manual Shuttoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 pound per square inch 3 5 kPa Connecting gas piping...

Страница 18: ...PVC parts should be assembled with ASTM D 2564 grade cement Assemble Vent Pipe Assemblies 1 2 and 3 See Figure 1 prior to cementing The preferred orientation of Vent Pipe Assembly 1 Condensate U Assem...

Страница 19: ...L Clearance above paved sidewalk or paved driveway located on public property 7 feet 2 13 m F Clearance to outside corner 2 feet 60 cm M Clearance under veranda porch deck or balcony 12 inches 30 cm G...

Страница 20: ...r signs of sagging or other stresses in joints as a result of misalignment of any components in system If any of these conditions are found they must be corrected in accordance with venting instructio...

Страница 21: ...tubing is still attached from the air pressure switch to the port on the blower housing Make sure the plastic tubing is not folded anywhere between the pressure switch and the blower housing 6 Make su...

Страница 22: ...ine This will allow the vent to easily slide through the opening The resulting gap will be covered up by the Vent Terminal cover plate Repeat this step on inside wall if necessary SEQUENCE OF INSTALLA...

Страница 23: ...ighest anticipated snow level install a snorkel as shown in bottom portion of Figure 20 NOTE With the installation of a snorkel it is necessary to use two 90 elbows that shall be considered along with...

Страница 24: ...cement not included with kit and glue the two inch PVC pipe coming from the blower into the VAA 3 Perform the same sequence on the PVC pipe coming from the exhaust side vent terminal side of the VAA 4...

Страница 25: ...and the vent pipe system Air leaks will allow flue gas by products to disseminate into the room creating an unsafe environment and could cause illness asphyxiation and or even death FIGURE 24 Typical...

Страница 26: ...above PRIMER It is recommended that Tetrahydrofuran THF be used to prepare the surfaces of pipe and fittings for solvent welding Do not use water rags gasoline or any other substitutes for cleaning PV...

Страница 27: ...make a second mark as the primer and cement will most likely destroy your first one Apply primer to the surface of the pipe and fitting socket with a natural bristle brush This process softens and pr...

Страница 28: ...28...

Страница 29: ...located in an area where the general public does not have access If a suitable area is not available a cover should be installed over the thermostat to prevent tampering Thewatertemperaturesettingwasf...

Страница 30: ...riod of time generally two weeks or more Hydrogen gas is extremely flammable and explosive To prevent the possibility of injury under these conditions we recommend the hot water faucet located farthes...

Страница 31: ...od which will slowly deplete due to electrolysis prolonging the life of the water heater by protecting the glass lined tank from corrosion Adverse water quality hotter water temperatures high hot wate...

Страница 32: ...essure Relief Valve must be installed in opening provided Can result in overheating and excessive tank pressure Can cause serious injury or death DRAINING AND FLUSHING It is recommended that the water...

Страница 33: ...ose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances wat...

Страница 34: ...heet 34 Wire Screen 3 35 Wire Screen 4 36 Wall Plate 4 37 Flexible Tubing REPAIR PARTS LIST Nowthatyouhavepurchasedthiswaterheater shouldaneedeverexistfor repairpartsorservice simplycontactthecompanyi...

Страница 35: ...3 Ensure maximum number of elbows or maximum equivalent feet of vent or intake air pipe has not been exceeded per the installation instructions in the manual that came with the water heater 4 Ensure...

Страница 36: ...alve s immersion probe is either open or shorted 1 Turn the power off for 10 20 seconds then on again to clear these error codes 2 Replace the gas control valve thermostat if the error code persists 1...

Страница 37: ...37 These guidelines should be utilized by a qualified service agent TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES...

Страница 38: ...38 TROUBLESHOOTING GUIDELINES NOTES...

Страница 39: ...of it in a modified form or any attempt to repair tank leaks or parts will void this warranty servIce and laBor responsIBIlItY UNDER THIS LIMITED WARRANTY THE WARRANTOR WILL PROVIDE ONLY A REPLACEMEN...

Страница 40: ...40 Copyright 2010 A O Smith Corporation All rights reserved 500 Tennessee Waltz Parkway Ashland City TN 37015 Technical Support 800 527 1953 Parts 800 433 2545 Fax 800 644 9306 www hotwater com...

Отзывы: