AUX HEATER ON TEMP-*
AUX HEATER ON TEMP
is the parameter which is used to determine whether the auxillary
heater should be enabled.
Setting Range: -5~30
℃
Default Value: 15
AUX HEATER TEMP ADJ-*
AUX HEATER TEMP ADJ
is the parameter which is used to determine whether the auxillary
heater should be enabled.
Setting Range: 3~8
℃
Default Value: 6
AUX HEATER DIFF-*
AUX HEATER DIFF
is the parameter which is used to determine whether the auxillary
heater should be enabled.
Setting Range: 1~4
℃
Default Value: 2
AUX HEATER-*
AUX HEATER
should be set as WITH or W/O based on the actual system installation.
Setting Options: WITH, W/O (Without)
Default Options: WITH
AUX HEATER TYPE-*
AUX HEATER TYPE
should be set to determine the auxillary heater control logic.
Setting Options: STORAGE, TANKLESS, STATIC
Default Options: TANKLESS
MANUAL DEFROST
MANUAL DEFROST
is the menu item which could enforce a defrosting cycle even the heat
pump unit does not have defrosting request.
Please refer to “MANUAL DEFROST OPERATION PROCESS” section for detailed setting
method.
HP TEMP ADJ-*
HP TEMP ADJ
is the parameter to adjust the maximum water temperature for the heat
pump based on the total operation time. It would be reset to 0 after the HX CLEAN RESET.
Setting Range: 0~2
℃
Default Value: 0
EX-FACTORY RESET
EX-FACTORY RESET
is the menu item to reset all the parameters to be the ex-factory
settings.
Please refer to “CENTREL CONTROLLOR EX-FACTORY RESET OPERATION PROCESS” section
for detailed setting method.
Note: Select the menu item by pressing the Up/Down buttons. When the menu is selected, it will be highlighted with the
white background, then press the “MODIFY” button to set the related parameters. Press the “BACK” button to return to
the main page of the interface and press the “HELP” button to enter the menu for help.
Please refer to “Summer Tank Temperature Setting” section for detailed setting method of menu items marked with *.
Содержание CAHP-MC-38
Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS AIR TO WATER HEAT PUMP WATER HEATER CAHP MC 38 ...
Страница 6: ...2 Physical Dimensions Picture 2 1 Unit Dimensions ...
Страница 13: ...Picture 5 4b ...
Страница 14: ...Picture 5 4c ...
Страница 55: ...9 Appendix 12 4 Heat Pump Unit Wiring Diagram Picture 9 1 Heat Pump Unit Wiring Diagram ...
Страница 57: ...Picture 9 3 Incorrect Communication Cable Wiring ...