6.2.
UIM Interface Introduction
The UIM interface includes two pages of display, the main page and the secondary page. The two pages
could be switched by pressing the UP/DOWN buttons. The UIM will display the main page as default.
Press the UP or DOWN button to go to the secondary page. If there is no operation for 10S when the
secondary page is displayed, the UIM will return to the main page automatically. Please refer to figure
3-1 for the details of the main page interface layout and contents.
Interface Description – Main Page
Area
Content
Function Description
Area①
Controller Title
Display the controller title.
Area①
Hot water
System
Parameters
TANK TEMP
Display the current tank temperature. Display the upper tank
temperature. It will display the control temperature, which is the lower
tank temperature if there is a control temperature fault.
AMBIENT
TEMP
Display the ambient temperature, which is the average value of the
ambient temperatures from all the heat pumps. It will display “
-10
℃
” if all the heat pump units have the ambient sensor fault.
HEAT PUMP
Display the current status of the heat pump units. There are totally six
status,
which
are:
“OFF”,
“HEATING”,
“DEFROST”,
“ANTI-FRZ”
(Anti-Freezing), “STANDBY” & SWITCH”.
AUX HEATER
Display the status of the auxillary heating equipment.
If the hot water system is installed with a auxillary heating equipemtn, it
will display the current status of the auxillary heating equipment. There
are totally three status, which are: “ON”, “STANDBY”, “OFF”.
If the hot water system is not installed with a auxillary heating
equipment, it will display “NONE”.
Auxiliary Heating Anti-Freezing Display:“ANTI-FRZ”.
FAULT INFO
Display the error Informations of the centrall controller and all the heat
pump units.
The error codes will be displayed alternatively with 2 seconds shift if
there are more than one error codes.
Please refer to the “error code table” for detailed description of the
errors.
A.O.SMITH HOT WATER SYSTEM
ON FUNC HELP
TANK TEMP 50℃
AMBIENT TEMP 22℃
HEAT PUMP STANDBY
AUX HEATER STANDBY
FAULT INFO NONE
TIME
MON
12
:
00
①
②
③
④
Picture 6.2 Main Page Layout & Display Content
Содержание CAHP-MC-38
Страница 1: ...INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS AIR TO WATER HEAT PUMP WATER HEATER CAHP MC 38 ...
Страница 6: ...2 Physical Dimensions Picture 2 1 Unit Dimensions ...
Страница 13: ...Picture 5 4b ...
Страница 14: ...Picture 5 4c ...
Страница 55: ...9 Appendix 12 4 Heat Pump Unit Wiring Diagram Picture 9 1 Heat Pump Unit Wiring Diagram ...
Страница 57: ...Picture 9 3 Incorrect Communication Cable Wiring ...