710 / 710 ASME Service Manual
Ver. 1.00
43
CONFIDENTIAL
Error Code
Malfunction description
Cancellation method
Pump failure
Turn off the power
Diagnosis
Checkpoint
631
1 Check whether the pump connected to PCB works properly.
Error Code
Malfunction description
Cancellation method
Water control valve fault
(Flow adjustment function)
(Only Easy-link and Multi-unit system)
Turn off the power or water supply
Diagnosis
Checkpoint
651
1 PCB and flow adjustment valve fault
(Refer to section 10-9 & 10-14)
Visual inspection of Water control valve: connection / breakage of wires,
motor drive locked due to scale buildup, and/or water leakage.
Normal: 13.0 to 16 VDC between (blue-brown)
Normal: ON:12.5 to 16.0 VDC / OFF: 0 to 1 V
Normal: 1 V Less than (0˚ position)
Visual inspection PCB: connection / breakage of wires and/or burn marks on
the computer board.
J
Error Code
Malfunction description
Cancellation method
Water control valve fault
(Bypass valve function)
Turn off the power or water supply
Diagnosis
Checkpoint
661
1 PCB and bypass valve fault
(Refer to section 10-9 & 10-14)
Visual inspection of Water control valve: connection / breakage of wires,
motor drive locked due to scale buildup, and/or water leakage.
Normal: 13.0 to 16 VDC between (blue-brown)
Normal: ON:12.5 to 16.0 VDC / OFF: 0 to 1 V
Normal: 1 V Less than (0˚ position)
Visual inspection PCB: connection/ breakage of wires and/or burn marks on
the computer board.
J