710 / 710 ASME Service Manual
Ver. 1.00
17
CONFIDENTIAL
10-3. Fan motor
Unit Part #
#115
AOS Part #
319143-043 Checkpoint
G
Function
To provide combustion air into the combustion chamber and to exhaust
flue gas.
Failure event
1. Fan speed failure, causing abnormal sounds with or without combustion
during operation.
2. Unexpected activation caused by the connectors of the fan motor getting
wet.
3. Disconnects from the bottom of the combustion chamber.
Effects on the water
heater if fan motor fails
1. The water heater does not function properly
2. Failure to ignite or abnormal ignition
3. Unstable combustion conditions
Error codes when the fan
motor fails
101 111 121 611 991
Diagnostic
1. Visual inspection: connection / breakage of wires or dust (causing
electrical shortage)
2. Voltage check: proper range of voltages shown below.
Red-Blue
110 to 160 VDC (Input)
Yellow-Blue
13 to 17 VDC (Input)
Orange-Blue
2.0 to 6.5 VDC (Input)
Color / Number of wires
White-Blue
Verify the fan motor speed using the Diagnostics Mode of
the temperature remote controller. See Section 12-1 for
details.
Fan damper (#116 / 319143-282)
PWN turbo fan motor
6
-
1
/
2
"
(
1
6
5
.
5
m
m
)
3 - 3 / 4 "( 9 5 .1 5 m m )
O p e n i n g 2 - 1 / 8 " ( 5 4 m m )
The fan damper
is not included in
319143-043.
1 -
3 /
4 "
(
4 6
m m
)
4 6