710 / 710 ASME Service Manual
Ver. 1.00
66
CONFIDENTIAL
12-14. Relay selection for the pump control connection
The maximum current capacity of the 710 models
pump control connection is 1 amp.
Before using relay with the pump control, please
check the specifications of that particular relay to
ensure that the current value through the coil will
not exceed 1 amp.
For example
To the right, there is a sample of relay
specifications from an arbitrary brochure. You
can select either the 120 VAC or 240 VAC relay,
because their current values are less than 1 A
(1,000 mA).
These components are not included with water
heaters and are external to the unit. They
must be acquired separately.
Through this circuit, the maximum current
capacity is 1 A
Power supply for relay
Normally 120 VAC
120 VAC
220 VAC etc
Thermal relay
Recirculation
pump
Connect to this “Pump” connector.
Power supply for pump
120 VAC
220 VAC etc