10-17. Igniter
Unit Part #
#125
AOS Part #
319143-052
Checkpoint
B
Function
-To ignite the gas / air mixtures when the water heater is ready to burn gas
on its burner surface.
-The output voltage of the igniter is more than 14 kVDC.
Failure event
1. Unable to ignite during the ignition process.
2. Makes attempts to ignite at all times.
Effects on the water
heater if the igniter fails
1. The water heater cannot ignite during the ignition process and the "111"
or "121" error codes will display.
2. No effects on the water heater, however, the durability of the igniter
wears down.
Error codes when Igniter
fails
111
121
Diagnostic
1. Visual inspection: connection / breakage of wires and /or an observed
weak spark.
2. Check voltages: proper range of values shown below.
Color / Number of wires
Purple(7)-Purple(7)
90 to 110 VAC
1 - 3 / 4 " ( 4 4 m m )
3
/
4
"
(
2
0
m
m
)
1
-
1
/
2
"
(
3
8
m
m
)
P o w e r s u p p l y
A C 9 0 t o 1 1 0 V
T o H i g h v a l t a g e
i g n i t e c a b l e
Igniter
High-voltage igniter cable
90 to 110VAC
14 kVDC
Purple wire
The high-voltage
igniter cable and
the purple wires
do not come with
319143-052.