background image

29

RESIDENTIAL GAS WARRANTY

THIS WARRANTY IS APPLICABLE TO THE ORIGINAL 
OWNER ONLY in accordance with the warranty terms and 
conditions speci

fi

 ed below.

The warrantor will furnish the ORIGINAL OWNER,  1) 
a replacement water heater of equivalent size and cur-
rent model if the glass-lined tank in this water heater 
leaks and,  2) a replacement part for any component 
part which fails.

THE WATER HEATER REPLACEMENT MODEL OR 
PART WILL BE WARRANTED FOR ONLY THE UNEX-
PIRED PORTION OF THE ORIGINAL WARRANTY.  The 
warranty period will be determined by the original date 
of purchase of the water heater, or in the absence of a 
Bill of Sale verifying said date, from the date of manu-
facture indicated on rating plate affixed to this water 
heater.  This warranty is not transferable and applies to 
models listed below:

SERIES

TANK

PARTS

ProMax 10-Year Models

XCV, XCVL, XCVH, XVR, 

XCVT, XCVX

10-Year

6-Year

ProMax 6-Year Models

GCV, GCVL, GCVH, GVR, 

GCVT, GCVX, GCNH, GNR, 

GDV, GDVT

6-Year

6-Year

When the water heater has been used for other than single 
family residential application;  

1.  The  tank warranty shall be reduced to 1 year for 6 year 

models.

2. The parts warranty shall be reduced to 1 year for all

models.

CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is in-
stalled and operated in accordance with 1) all local 

fi

 re codes 

and plumbing codes, ordinances and regulations, 2) the 
printed instructions provided with it, 3) good industry practic-
es, and 4) proper safety practices such as but not limited to a 
properly sized drain pan if installed in an area where leakage 
from the tank or its connections would result in damage to 
the area adjacent to the heater.  In addition, a new tempera-
ture and pressure relief valve, certi

fi

 ed by the Canadian Gas 

Association must have been properly installed and piped to 
the nearest drain.

This warranty shall apply only when the heater is:
•  owned by the original purchaser;
•  installed for indoor operation only;
•  used at temperatures not exceeding the maximum

calibrated setting of its thermostat;

•  used at water pressure not exceeding the working

pressure shown on the heater;

• 

fi

 lled with potable water, free to circulate at all times and 

with the tank free of damaging water sediment or scale
deposits;

• used in a non-corrosive and non-contaminated 

atmosphere;

•  used with factory approved anode(s) installed;
•  in its original installation location;
•  in the United States, its territories or possessions, and  

Canada;

•  sized in accordance with proper sizing techniques for  

residential water heaters;

•  bearing a rating plate which has not been altered,

defaced or removed except as required by the warrantor;

•  used in an open system or in a closed system with a  

properly sized and installed thermal expansion tank;

•  operated with properly installed drip leg in the gas supply  

line;

• 

fi

 red with the fuel for which it was factory built;

• 

fi

 red at the factory rated input;

• operated with the inner and outer combustion

chamber doors in place and all factory seals to combus-
tion  chamber intact.

•  installed with no attempted, nor actual modi

fi

 cation  or 

alteration of the water heater’s design in any way, includ-
ing but not limited to, the attachment of non-company 
approved appliances or equipment.

Any accident to the water heater or any part thereof (includ-
ing freezing, 

fi

 re, 

fl

 oods, or lightning), any misuse, abuse or 

alteration of it, any operation of it in a modi

fi

 ed form, any 

operation of the water heater on desalinated (deionized) 
water, or any damage caused by attempts to repair tank 
leaks or parts, will void this warranty.  This warranty does 
not cover water heaters replaced for cosmetic reasons or for 
reasons of noise, taste, odor, discolored and/or rusty water.  
This warranty does not apply to water heaters used to heat 
pools, whirlpools or hot tubs or used for space heating where 
its sizing does not conform with speci

fi

 cations of the heating 

component manufacturer.

This warranty gives you speci

fi

 c legal rights, and you may 

have other rights which vary under the laws of each state. If 
any provision of this warranty is prohibited or invalid under 
applicable state law, that provision shall be ineffective to the 
extent of the prohibition or invalidity without invalidating the 
remainder of the affected provision or the other provisions of 
this warranty.

Содержание 186589-004

Страница 1: ...fety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER GAMA certification applies to all residential gas water heat ers with capacities of 20 to 100 gallons with input rating of 75 000 BTU Hr o...

Страница 2: ...it relates to the installation of gas fired water heaters The qualified installer must also be familiar with the design features and use of flammable vapor ignition resistant water heaters and have a...

Страница 3: ...3 GENERAL SAFETY...

Страница 4: ...iation ANSI American National Standards Institute NFPA National Fire Protection Association ASME American Society of Mechanical Engineers GAMA Gas Appliance Manufacturer s Association UL Underwriters...

Страница 5: ...TALL PER LOCAL CODES THERMAL EXPANSION TANK INSTALLTHERMALEXPANSION TANK IF WATER HEATER IS INSTALLED IN A CLOSED SYSTEM GAS CONTROL GAS PILOT MAIN BURNER PILOT PIEZO ELECTRODE THERMOCOUPLE FLUE BAFFL...

Страница 6: ...a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as...

Страница 7: ...environment in which the water heater is installed Wa ter heaters are sometimes installed in locations where leakage may result in property damage even with the use of a drain pan piped to a drain Th...

Страница 8: ...a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 cm per kW of the aggregate input rating of all appliances installed in that space VENT TERMINATION Before installing water h...

Страница 9: ...ny heating systems or component s used with a non potable water heating appli ance All piping components connected to this unit for space heating applications shall be suitable for use with potable wa...

Страница 10: ...TEMPERATURE PRESSURE RELIEF VALVE This heater is provided with a properly certified combination temperature pressure relief valve by the manufacturer The valve is certified by a nationally recognized...

Страница 11: ...and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and re place the temperature pressure relief valve with a new one WATER POTAB...

Страница 12: ...ution and wipe dry Wheninstalledatelevationsabove7 700feet 2 347meters input rating should be reduced at the rate of 4 percent for each 1 000 feet 305 meters above sea level which requires replacement...

Страница 13: ...ank must be filled with water Water must flow from the hot water faucet before turning ON gas to the water heater To fill the water heater with water 1 Close the water heater drain valve by turning th...

Страница 14: ...1 cm above if within 10 ft 3 m horizontally to a mechanical air supply inlet Minimum 12 in 30 cm from sides above or below a permanently closed window or door Minimum 7 ft 2 3 m above public sidewalk...

Страница 15: ...72m 68 in for 40 gal models and 1 93m 76 in for 50 gal 50 gal Hi Input and 75 gal models The maximum distance recommended is 2 03m 80 in or in compliance with Figure 16 Where the wall is combustible a...

Страница 16: ...junction of the outer corrugated tube and the trim plate inside with suitable sealant SEALANT TRIM PLATE INSIDE TRIM PLATE OUTSIDE FIGURE 19 UNCOMPRESSING THE CORRUGATED TUBING 1 Pull the inner corrug...

Страница 17: ...corrugated tube TOP VIEW 90 MAXIMUM BEND FIGURE 26 CONDITION 2 Where floor joists impede venting a rise or drop to complete the vent termination is possible All installations require 25mm 1 in clearan...

Страница 18: ...r door 12 Set thermostat to desired setting 13 If the pilot will not stay lit after several tries turn the gas control knob clock wise to OFF see Figure A If the appliance will not operate follow the...

Страница 19: ...ter uses can cause temperatures at the point of use to exceed the thermostat setting by up to 17 C 30 F If you experience this type of use you should consider using lower temperature settings to reduc...

Страница 20: ...effects of water hammer among others have installed devices such as pressure reducing valves check valves back flow preventers etc to control these types of problems When these devices are not equipp...

Страница 21: ...ssibility of injury under these conditions we recommend the hot water faucet located farthest away be opened for several minutes before any electri cal appliances which are connected to the hot water...

Страница 22: ...er heater will create dangerous conditions which can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAM AGE Contact a qualified installer or service agency to replace a flooded water heater Do not atte...

Страница 23: ...ater to run until it flows clean This will help prevent sediment build up in the tank It is normal for lime and scale deposits to form within the tank Such deposits will not be removed by periodic dra...

Страница 24: ...er heater 2 Follow Draining instructions 3 Turning counterclockwise remove the hex cap below the screw handle 4 Remove the washer and put the new one in place 5 Screw the handle and cap assembly back...

Страница 25: ...er from temperature pressure relief valve may be due to thermal expansion or high water pres sure in your area D The temperature pressure relief valve may be leaking at the tank fitting E Water from a...

Страница 26: ...gas utility company 3 Notify utility install dirt trap in gas line 4 Clean locate source and correct 5 Finger tighten then 1 4 turn with wrench 6 Replace thermocouple 7 Locate source and correct 8 Re...

Страница 27: ...3 Heater installed in a confined area 1 Provide ventilation to water heater Check flue way flue baffle burner 2 Clean locate source and correct 3 Provide fresh air ventilation SMOKING AND CARBON FORM...

Страница 28: ...28 NOTES...

Страница 29: ...used at water pressure not exceeding the working pressure shown on the heater filled with potable water free to circulate at all times and with the tank free of damaging water sediment or scale depos...

Страница 30: ...nt 125 Southeast Parkway Franklin TN 37068 phone 1 800 433 2545 The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or distributed...

Страница 31: ...31 500 TENNESSEE WALTZ PARKWAY ASHLAND CITY TN 37015 PHONE 1 800 433 2545 FAX 1 800 433 2515 www aosmithwaterheaters com email parts hotwater com...