EXTERNAL DAMAGE

Do not operate the water heater until it has been fully checked 
out by a quali

fi

 ed technician, if the water heater:

•  Has been exposed to 

fi

 re or damage.

•  Displays evidence of sooting.
•  Produces steam or unusually hot water.

If the water heater has been 

fl

 ooded it must be replaced.

START UP CONDITIONS

NEVER OPERATE THE HEATER WITHOUT FIRST BEING 
CERTAIN IT IS FILLED WITH WATER AND A TEMPERATURE 
AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RE-
LIEF VALVE OPENING OF THE HEATER.  DO NOT ATTEMPT 
TO OPERATE HEATER WITH COLD WATER INLET VALVE 
CLOSED.

CONDENSATE

Whenever the water heater is 

fi

 lled with cold water, some con-

densate will form while the burner is on. A water heater may 
appear to be leaking when in fact the water is condensate. This 
usually happens when:

a.  A new water heater is 

fi

 lled with cold water for the 

fi

 rst time.

b.  Burning gas produces water vapor in water heaters, par-

ticularly high ef

fi

 ciency models where 

fl

 ue temperatures are 

lower.

c.  Large amounts of hot water are used in a short time and the 

re

fi

 ll water in the tank is very cold.

Moisture from the products of combustion condense on the 
cooler tank surfaces and form drops of water which may fall 
onto the burner or other hot surfaces to produce a “sizzling” or 
“frying” noise.

Because of the suddenness and amount of water, condensate 
water may be diagnosed as a “tank leak”. After the water in the 
tank warms up (about 1-2 hours), the condition should disap-
pear.

Do not assume the water heater is leaking until there has been 
enough time for the water in the tank to warm up.

An undersized water heater will cause more condensation. The 
water heater must be sized properly to meet the family’s de-
mands for hot water including dishwashers, washing machines 
and shower heads.

Excessive condensate may be noticed during the winter and 
early spring months when incoming water temperatures are at 
their lowest.

Good venting is essential for a gas 

fi

 red water heater to operate 

properly as well as to carry away products of combustion and 
water vapor.

SMOKE/ODOR

It is not uncommon to experience a small amount of smoke and 
odor during the initial start-up. This is due to burning off of oil 
from metal parts, and will disappear in a short while.

THERMAL EXPANSION

Water supply systems may, because of such events as high line 
pressure, frequent cut-offs, the effects of water hammer among 
others, have installed devices such as pressure reducing valves, 
check valves, back 

fl

 ow preventers, etc. to control these types of 

problems. When these devices are not equipped with an internal 
by-pass, and no other measures are taken, the devices cause 
the water system to be closed. As water is heated, it expands 
(thermal expansion) and closed systems do not allow for the 
expansion of heated water.

The water within the water tank expands as it is heated and in-
creases the pressure of the water system. If the relieving point of 
the water heater’s temperature-pressure relief valve is reached, 
the valve will release the excess pressure. The temperature-
pressure relief valve is not intended for the constant relief of 
thermal expansion. This is an unacceptable condition and must 
be corrected. It is recommended that any devices installed which 
could create a closed system have a by-pass and/or the system 
have an expansion tank or device to relieve the pressure built 
by thermal expansion in the water system. Expansion tanks 
are available for ordering through a local plumbing contractor. 
Contact the local water heater supplier or service agency for as-
sistance in controlling these situations.

STRANGE SOUNDS

Possible noises due to expansion and contraction of some metal 
parts during periods of heat-up and cool-down do not necessarily 
represent harmful or dangerous conditions.

Condensation causes sizzling and popping within the burner 
area during heating and cooling periods and should be consid-
ered normal. See “Condensate” in this section.

OPERATIONAL CONDITIONS

SMELLY WATER

In each water heater there is installed at least one anode rod 
(see parts section) for corrosion protection of the tank. Certain 
water conditions will cause a reaction between this rod and the 
water. The most common complaint associated with the anode 
rod is one of a “rotten egg smell” in the hot water. The smell is 
a result of four factors which must all be present for the odor to 
develop:

a.  A concentration of sulfate in the supply water.
b.  Little or no dissolved oxygen in the water.
c.  A sulfate reducing bacteria which has accumulated within the 

water heater (this harmless bacteria is nontoxic to humans).

d.  An excess of active hydrogen in the tank. This is caused by 

the corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater 
models by replacing the anode(s) with one of less active mate-
rial, and then chlorinating the water heater tank and all water 

FOR YOUR INFORMATION

Содержание 186589-004

Страница 1: ...fety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER GAMA certification applies to all residential gas water heat ers with capacities of 20 to 100 gallons with input rating of 75 000 BTU Hr o...

Страница 2: ...it relates to the installation of gas fired water heaters The qualified installer must also be familiar with the design features and use of flammable vapor ignition resistant water heaters and have a...

Страница 3: ...3 GENERAL SAFETY...

Страница 4: ...iation ANSI American National Standards Institute NFPA National Fire Protection Association ASME American Society of Mechanical Engineers GAMA Gas Appliance Manufacturer s Association UL Underwriters...

Страница 5: ...TALL PER LOCAL CODES THERMAL EXPANSION TANK INSTALLTHERMALEXPANSION TANK IF WATER HEATER IS INSTALLED IN A CLOSED SYSTEM GAS CONTROL GAS PILOT MAIN BURNER PILOT PIEZO ELECTRODE THERMOCOUPLE FLUE BAFFL...

Страница 6: ...a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as...

Страница 7: ...environment in which the water heater is installed Wa ter heaters are sometimes installed in locations where leakage may result in property damage even with the use of a drain pan piped to a drain Th...

Страница 8: ...a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 cm per kW of the aggregate input rating of all appliances installed in that space VENT TERMINATION Before installing water h...

Страница 9: ...ny heating systems or component s used with a non potable water heating appli ance All piping components connected to this unit for space heating applications shall be suitable for use with potable wa...

Страница 10: ...TEMPERATURE PRESSURE RELIEF VALVE This heater is provided with a properly certified combination temperature pressure relief valve by the manufacturer The valve is certified by a nationally recognized...

Страница 11: ...and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and re place the temperature pressure relief valve with a new one WATER POTAB...

Страница 12: ...ution and wipe dry Wheninstalledatelevationsabove7 700feet 2 347meters input rating should be reduced at the rate of 4 percent for each 1 000 feet 305 meters above sea level which requires replacement...

Страница 13: ...ank must be filled with water Water must flow from the hot water faucet before turning ON gas to the water heater To fill the water heater with water 1 Close the water heater drain valve by turning th...

Страница 14: ...1 cm above if within 10 ft 3 m horizontally to a mechanical air supply inlet Minimum 12 in 30 cm from sides above or below a permanently closed window or door Minimum 7 ft 2 3 m above public sidewalk...

Страница 15: ...72m 68 in for 40 gal models and 1 93m 76 in for 50 gal 50 gal Hi Input and 75 gal models The maximum distance recommended is 2 03m 80 in or in compliance with Figure 16 Where the wall is combustible a...

Страница 16: ...junction of the outer corrugated tube and the trim plate inside with suitable sealant SEALANT TRIM PLATE INSIDE TRIM PLATE OUTSIDE FIGURE 19 UNCOMPRESSING THE CORRUGATED TUBING 1 Pull the inner corrug...

Страница 17: ...corrugated tube TOP VIEW 90 MAXIMUM BEND FIGURE 26 CONDITION 2 Where floor joists impede venting a rise or drop to complete the vent termination is possible All installations require 25mm 1 in clearan...

Страница 18: ...r door 12 Set thermostat to desired setting 13 If the pilot will not stay lit after several tries turn the gas control knob clock wise to OFF see Figure A If the appliance will not operate follow the...

Страница 19: ...ter uses can cause temperatures at the point of use to exceed the thermostat setting by up to 17 C 30 F If you experience this type of use you should consider using lower temperature settings to reduc...

Страница 20: ...effects of water hammer among others have installed devices such as pressure reducing valves check valves back flow preventers etc to control these types of problems When these devices are not equipp...

Страница 21: ...ssibility of injury under these conditions we recommend the hot water faucet located farthest away be opened for several minutes before any electri cal appliances which are connected to the hot water...

Страница 22: ...er heater will create dangerous conditions which can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAM AGE Contact a qualified installer or service agency to replace a flooded water heater Do not atte...

Страница 23: ...ater to run until it flows clean This will help prevent sediment build up in the tank It is normal for lime and scale deposits to form within the tank Such deposits will not be removed by periodic dra...

Страница 24: ...er heater 2 Follow Draining instructions 3 Turning counterclockwise remove the hex cap below the screw handle 4 Remove the washer and put the new one in place 5 Screw the handle and cap assembly back...

Страница 25: ...er from temperature pressure relief valve may be due to thermal expansion or high water pres sure in your area D The temperature pressure relief valve may be leaking at the tank fitting E Water from a...

Страница 26: ...gas utility company 3 Notify utility install dirt trap in gas line 4 Clean locate source and correct 5 Finger tighten then 1 4 turn with wrench 6 Replace thermocouple 7 Locate source and correct 8 Re...

Страница 27: ...3 Heater installed in a confined area 1 Provide ventilation to water heater Check flue way flue baffle burner 2 Clean locate source and correct 3 Provide fresh air ventilation SMOKING AND CARBON FORM...

Страница 28: ...28 NOTES...

Страница 29: ...used at water pressure not exceeding the working pressure shown on the heater filled with potable water free to circulate at all times and with the tank free of damaging water sediment or scale depos...

Страница 30: ...nt 125 Southeast Parkway Franklin TN 37068 phone 1 800 433 2545 The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or distributed...

Страница 31: ...31 500 TENNESSEE WALTZ PARKWAY ASHLAND CITY TN 37015 PHONE 1 800 433 2545 FAX 1 800 433 2515 www aosmithwaterheaters com email parts hotwater com...

Отзывы: