17
A
NEU
VIDEO
ETHERNET & rs-232 SERIAL INTERFACE
ETHERNET / RS-232 SERIAL INTERFACE CONNECTS a PC or CONTROL SYSTEM
VERSION COMPATIBLE V2.0
For a complete list of commands, please reference external document extended Ethernet Protocol Instruction Manual.
Example of the commanded string to select Inputs:
FUNCTION
COMMAND
VARIABLES
Select source
Source xxx;
xxx = Input Channel (001=Source1, 002=Source2.etc)
COMMAND EXAMPLE
RESPONSE
DESCRIPTION
Source 001;
Source 001#ok;
Select source number 1
ETHERNET SERIAL INTERFACE
Pin
Ethernet
Reference
1
TxOP
Tx +
2
TxON
Tx -
3
RxIP
Rx +
4
NC
5
NC
6
RxIN
Rx -
7
NC
8
GND
ETHERNET TCP/IP PROTOCOL COMMANDS ( Ethernet / RS-232 Control driver V2.0 )
*** The Ethernet port and RS-232 port cannot be used simultaneously. Any connection to the Ethernet Control port will disable serial
commands sent to the RS-232 port.***
RS-232 Configuration
RS-232 cable is a straight thru cable and not null-modem
Definition
Pin
Pin
Definition
1
1
DCD
Tx
2
2
Rx
Rx
3
3
Tx
4
4
DTR
GND
5
5
GND
6
6
DSR
7
7
RTS
8
8
CTS
9
9
RI
RS-232 SERIAL INTERFACE PROTOCOL COMMANDS ( Ethernet / RS-232 Control driver V2.0 )
The HD-88K switcher can be controlled via the RS-232 serial control port to allow for interfacing to a PC, or similar third party control
system. The serial communication parameters are 9600 baud, 8 bit, No Parity and 1 stop bit - this is often referred to as 9600 8N1. When
the unit recognizes a complete command it will perform the requested action - there is no delimiter character required.
Note:
Control the switcher
SPD: Speed
LINK: Ethernet link
RJ-45 Female 8P-8C Connector
HD-88K
Device
PC
TCP, Port 5000