If problem persists after trying the above solutions, contact your nearest authorized
service center for assistance.
ENGINE WILL NOT START
Possible Cause
Solution
Engine switch is in the OFF position.
Turn engine switch to the ON position.
No fuel.
Fill fuel tank.
Multi-switch is in OFF or Run position.
Turn multi-switch to the START position.
Dirty fuel filter.
Replace fuel filter or contact a qualified service center.
Spark plug faulty, fouled, or
improperly gapped.
Replace spark plug.
Drain fuel. Refuel with fresh gasoline.
Engine stored without treating or
draining gasoline, or refueled with
bad gasoline.
Drain fuel. Refuel with fresh gasoline. If problem
continues, contact a qualified service center.
Engine stored without treating or
draining gasoline, or refueled with
bad gasoline.
Stale gasoline or water in gasoline.
Drain entire system and refill with fresh fuel.
Engine oil level is low.
Engine is equipped with Low Oil Shutoff. If engine
oil level is low, it must be filled before unit will start.
Check engine oil level and fill, if necessary.
Battery not charged.
Charge battery.
ENGINE LACKS POWER.
Possible Cause
Solution
Dirty air filter.
Check air filter element. Clean or replace as needed.
AC Circuit protector(s) tripped.
GFCI system activated.
Item plugged in is defective.
AC RECEPTACLE DOES NOT WORK.
Possible Cause
Solution
OUTPUT indicator is OFF, and
OVERLOAD indicator is ON.
Check AC load. Stop and restart the engine. Check
the cooling air inlet. Stop and restart the engine.
Check AC load and reset AC circuit protector(s)
Reset the GFCI.
Try a different item.
TROUBLESHOOTING
35
A-iPower Corp. 10887 Commerce Way Unit A Fontana, CA 92337 USA
www.a-ipower.com 1-855-888-3598 or [email protected].
Содержание SUA8000iE