GENERAL MAINTENANCE
Keep the generator in a clean and dry
environment where it is not exposed to
dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the
generator to become clogged with
foreign material such as leaves, etc.
Do not use a garden hose to clean the
generator. Water entering the fuel
system or other internal parts of the unit
can cause problems that will decrease
the life of the generator.
CHECKING/CLEANING AIR FILTER
For proper performance and long life,
keep air filter clean.
Loosen the screws at the side of the
right maintenance cover. Remove
cover and set aside.
Reinstall the air filter cover.
Reinstall the right maintenance
cover. Tighten screws to secure.
Unsnap the air filter cover clip, pulling
the cover down and off the unit,
remove air filter cover and set aside.
Remove the air filter.
Wash the air filters with warm, soapy
water. Rinse and squeeze to dry.
Reinstall the air filters.
NOTE:
Make sure the filters are
seated properly inside the generator.
Installing the filters incorrectly will
allow dirt to enter the engine, causing
rapid engine wear.
WARNING:
When servicing, use only identical
replacement parts. Use of any other
parts could create a hazard or cause
product damage.
MAINTENANCE
Right
maintenance
cover
CHANGING ENGINE OIL
For best performance, engine oil should
be changed after every 100 hours or 6
months of operation.
NOTE:
Drain the engine oil while the
engine is still warm but not hot. Warm
engine oil will drain quickly and more
completely.
Loosen the screws at the side of the
left maintenance cover. Remove
cover and set aside.
29
A
D
B
C
A-iPower Corp. 10887 Commerce Way Unit A Fontana, CA 92337 USA
www.a-ipower.com 1-855-888-3598 or [email protected].