Loosen the screws at the side of the
right maintenance cover. Remove
cover and set aside.
Turn the Multi-switch to the RUN
position.
Position a suitable container under
the carburetor drain screw to catch
fuel; loosen the screw.
Turn the Multi-switch to the OFF
position.
Make sure engine and exhaust of
unit is cool.
Keep the generator level to reduce
the possibility of fuel leakage.
When using ropes or tie-down straps
to secure the generator for
transportation, be sure to only use
the frame bars as attachment points.
Do not fasten ropes or straps to any
portions of the generator body or the
folding transport handle.
DRAINING FUEL TANK /
CARBURETOR
To help prevent gum deposits in the fuel
system, drain the fuel from the tank and
carburetor before storing.
TRANSPORTING
Draining the fuel tank:
Remove the fuel tank cap, remove the
fuel strainer, and empty the fuel tank into
an approved gasoline container. We
recommend using a commercially
available gasoline hand pump to empty
the tank. Do not use an electric pump.
Siphon the gasoline by inserting the tip
of the hand pump into the side of the
pump guard. Reinstall the fuel strainer
and the fuel tank cap..
Draining the carburetor:
MAINTENANCE
Install the spark arrester in the
reverse order of removal.
Allow fuel to drain completely into
container.
Retighten drain screw securely.
Turn the Multi-switch to the OFF
position.
32
A-iPower Corp. 10887 Commerce Way Unit A Fontana, CA 92337 USA
www.a-ipower.com 1-855-888-3598 or [email protected].