Operating and Assembly Instructions – A.B.S. Flexilo ECO for wood pellets
Assembly
Subject to technical change
Issue 09/2016
Page 21 of 32
©A.B.S. Silo- und Förderanlagen GmbH
Attaching the silo bag
5.4 Attaching the silo cover to the ceiling
Attach the silo cover to the ceiling with the aid of ceiling hooks or a pipe slid through the
loops resp. on the support structure for the cover loops.
The contact surface of the retaining angle (for the impact wall
suspension) on the bar must be at least 150 mm.
THE SUSPENSION POINTS OF THE LOOPS (i.e. also the inserted
pipe) should be installed approx. 20 cm ABOVE THE FRAME.
Make sure that there are not sharp objects on the ceiling that could damage the silo cover.
Take particular care to attach the 3 loops for the baffle that is sewn into the cover
fabric opposite the filler neck.
Take care of the position of the supporting loops prior to attach the ceiling-holders to the
spread silo.
The loops must be attached one at a time during the following steps.
ATTENTION: Take care of the lifting bar with the boreholes for fastening the filling-
set. Loop it at the correct position.
Before continuing with assembly of the top bars, make the necessary preparations
to attach the fabric cover of the silo to the ceiling by means of the loops.
This step is not applicable when you work with the support structure (see price list
accessories) for the cover loops.