GIGASYNC MANUAL 

VER. 3 REV. 1 

 

Synchronization 

Many telecommunication networks require synchronization precision for their correct operation and, therefore, avoid self-
interference  and  reduce  noise  generated  by  the  network.  In  this  way,  frequencies  can  also  be  reused  and  spectrally 
efficient. This is possible to achieve if co-located devices are synchronized. 
 
To synchronize the equipment, you must have a standard signal that serves as a reference to accurately determine the 
corresponding data send and receive slots. This signal is known as a sync pulse and it will allow all synchronized devices to 
send and receive data in the same period of time: uplink (sending data) and downlink (receiving data) so that when one 
receives information, none of the others are sending. 
 
The reference signal to generate the synchronization pulse, also known as "1PPS" or "pulse per second", can be obtained in 
different ways: 

 

Through the external GPS antenna 

 

Through the GigaSync “Sync Input” port, connecting: 

o

 

“Sync output” port of other GigaSync 

o

 

Cambium Networks uGPS 

o

 

Cambium Networks cnPulse  

o

 

Cambium Networks CMM5 

 

With this sync pulse, the GS-G-POE-CS and GS-G-TER-CS cartridges can perfectly replicate the Cambium Networks sync 
modes as described in the following table: 

 

GS-G-POE-CS 

External antenna 

Sync Input 

Method of synchronization

 

GPSA 

(*) 

GigaSync 

 uGPS 

cnPulse 

CMM5 

Canopy Sync 

 

 

 

(§) 

 

 

Cambium Sync 

 

 

 

(§) 

 

 

 

 

 

 

Table 7 – Several ways to obtain Cambium Networks synchronization methods with GS-G-POE-CS

 

GS-G-TER-CS

 

External antenna 

Sync Input 

Method of synchronization 

GPSA 

(*)

 

GigaSync 

uGPS 

cnPulse 

CMM5 

Cambium Sync 

 

 

 

(§)

 

 

 

 

 

 

 

Table 8 - Several ways to get Cambium Sync with GS-G-TER-CS

 

(*) Product sold by 9dot. It must be purchased separately. 

(§) It depends on the source of synchronization that provides the pulse. 

 

GPS antenna 

The external antenna must be connected to the N-type female connector that is installed on the back of the GigaSync and 
requires a good view of the sky. It does not need to be mounted at the highest point of the tower.   
The external antenna will also give us the position and the satellites that will be reflected in the interface. 
 
9dot provides a GigaSync compatible GPS antenna model and coaxial cables to connect the antenna to the chassis. As 
detailed below: 
 

Product code (*) 

Description 

GS-GPSA 

Universal GPS antenna with mounting kit 

N2N5LMR 

RF Cable 400 N/M - N/M Length. 5mt 

N2N10LMR 

RF Cable 400 N/M - N/M Length. 10mt 

N2N20LMR 

RF Cable 400 N/M - N/M Length. 20mt 

Table 9 - GPS antenna and coaxial cables supplied by 9dot

 

(*) These items are not part of the GigaSync supply, they must be ordered separately. 

Содержание GigaSync

Страница 1: ...1 GIGASYNC MANUAL VER 3 REV 1...

Страница 2: ...10 Injector Gigabit cartridge GS G POE GS G POE CS 10 Terminal s cartridge GS G TER 11 Terminal s cartridge with synchronization GS G TER CS 12 Cartridge label 13 Technical specifications 14 Installat...

Страница 3: ...ect with the GigaSync 28 Command line interface 28 Access 28 Menu 30 SNMP interface 31 Web interface 32 Connection 32 Access 32 Interface description 33 Options bar 34 Synoptic diagram 37 Modules 38 S...

Страница 4: ...e been made in the preparation of this document to ensure its accuracy 9dot assumes no responsibility for errors or omissions in this document or the use of the information contained therein 9dot rese...

Страница 5: ...ork alone in dangerous conditions Only qualified personnel may install use and repair this system and its components Always assume electrical connections or conductors are live Turn off all switches a...

Страница 6: ...r microswitches Hot swap modularity can manage up to 12 ports PoE or bipolar terminals The dual processor guarantees an interrupted operation of the unit in all the situations Remote management save t...

Страница 7: ...works synchronization GigaSync can insert into the PoE ports the sync pulse used by Cambium Networks devices to sync the transmission Manages any type of PoE Each port can be configured to handle a di...

Страница 8: ...t people and equipment For the correct operation of the dischargers it is necessary to connect the ground terminal GND Can be seen in the redundant power supply connectors of the base unit and the res...

Страница 9: ...to detect the SSID Wi Fi signal of the type GSvx_ serial The software ID is a unique identification of the device Indications by the standards FCC CE e RoHS The indications of power requirements and t...

Страница 10: ...Each PoE port has signaling LED that provides information on the status of the port on any faults and in the case of the POE CS version on the type of synchronization chosen On both sides there are s...

Страница 11: ...provides information on the status of the door and any faults Each connector can be removed from the terminals for easier manipulation Through the main connector located behind the module is connecte...

Страница 12: ...ignaling LED that provides information on the status of the port on any faults and if Cambium Sync synchronization is active or not Each connector can be removed from the terminals for easier manipula...

Страница 13: ...TER or GS G TER CS with a brief description The serial number of the cartridge The power requirements voltage and current Type and range of output voltage and current Operating temperature range Indi...

Страница 14: ...ce of voltage at the input SYNCHRONIZATION SPECIFICATIONS GPS external connector Type N female Sync input compatibility GigaSync of 9dot uGPS cnPulse and CMM5 of Cambium Networks Sync connectors Sync...

Страница 15: ...ec Gigabit transformer Transmission speed 10BaseT 100BaseT 1000BaseT Canopy Sync n a Cambium Sync n a CARTRIDGES TER Product code GS G TER GS G TER CS Type Terminal Terminal Ports 4 4 Connector type T...

Страница 16: ...s cartridge each port can power a device that consumes up to 3A and this is true However special care must be taken because in this case the total current will be limited by the typical cartridge curr...

Страница 17: ...ed to the base structure with the supplied fixing screws Likewise the main connector offers enough strength to prevent them from inadvertently pulling out To remove the cartridge firmly pull the remov...

Страница 18: ...e GigaSync are considered the first 3 LEDs arranged vertically to the left of the front LED Color Description SYNC flashing green 200ms Presence of sync pulse in selected input GPS or SYNC IN STATUS f...

Страница 19: ...se unit are accessible through two redundant connectors are isolated from each other and no conversion is made to the applied voltage In this way it is possible to simultaneously connect different typ...

Страница 20: ...an be powered through the main input via redundant terminals The main input of the base unit has an isolated DCDC converter that powers the two CPUs In this way maximum immunity against over voltages...

Страница 21: ...ion Double phase protection is a circuit protection technology for high voltage environments Both technologies combined offer us great advantages to protect each port from voltage spikes The GigaSync...

Страница 22: ...ated on the data cable side and also protects against overvoltages avoiding the passage of emissions conducted up to the insulation voltage Adding to the GigaSync another strong point in terms of prot...

Страница 23: ...y has been designed to avoid handling the microswitches or jumpers that normally perform this function but are subject to errors This simplifies selection and executable simply by inserting the chosen...

Страница 24: ...t is possible to power each cartridge with a different voltage than the rest Power supply and synchronization GS G TER CS In addition to guaranteeing all the functions of the GS G TER cartridge it off...

Страница 25: ...e the Cambium Networks sync modes as described in the following table GS G POE CS External antenna Sync Input Method of synchronization GPSA GigaSync uGPS cnPulse CMM5 Canopy Sync Cambium Sync Table 7...

Страница 26: ...is used to replicate the sync pulse regardless of how it was acquired The pinout is as follows Pinout Sync Output RJ12 Pin Sync Voltage range 1 TX 5V DC 2 n c 3 n c 4 n c 5 GND 6 GND Table 11 GigaSync...

Страница 27: ...he Sync Output port of the other and vice versa This way in case of problems with one of the antennas coaxial cable internal GPS etc It will be possible remotely to re establish synchronization from t...

Страница 28: ...ugh the web interface It is also possible to query and configure the system using the SNMP and API protocols Command line interface The SSH interface allows you to control some accessible parameters o...

Страница 29: ...ing that the IP address has been permanently added to the list of known hosts After that it will ask us for the password and we must enter the default one password As soon as you log in the 9dot logo...

Страница 30: ...ackages Displays the list of valid packages loaded upgrade The software update procedure begins Users o add Add a new user o edit Edit an existing user o list Show user list o remove Remove a user Wif...

Страница 31: ...the operation of the interface you can execute a walk snmp command from the SSH shell using the IP of the GigaSync snmpwalk v 3 l authNoPriv u admin a sha A password m genmib mib IP GigaSync 1 3 6 1...

Страница 32: ...Fi are enabled by default and can be disabled from the interface The web interface works with the following browser version and later Chrome Version 91 0 4472 114 Official build x86_64 Firefox 87 0 64...

Страница 33: ...e to monitor in real time the applied voltage and the load parameters and to send commands of on off power cycle and synchronization Interpretation of the data is further facilitated by the ability to...

Страница 34: ...ttons on the bar below Stop The Stop button deactivates all GigaSync outputs After pressing it it will ask if we are sure ATTENTION This deactivates all outputs of the GigaSync but does not disconnect...

Страница 35: ...diagnosis IMPORTANT NOTE To automatically synchronize the day and time of the log GigaSync must be connected to a network with internet access User The user option allows access to some actions relate...

Страница 36: ...ult login credentials Reboot Hardware Full hardware reset Without turning off the doors Reboot Restarts all services software only does not affect hardware Sign out Close the session directly and the...

Страница 37: ...race the exact component as needed or in case of failure It also indicates the presence of the power supply and the sync source depending on CMD module base unit o Blue circle indicates power supply v...

Страница 38: ...or confirmation with a sign like the following If this is not displayed the change may not have been made General information View general GigaSync information including input line voltage and total o...

Страница 39: ...tify the variation and also shows the current value Free RAM memory of the control module in Bytes Data on the software and firmware version of the 2 CPU Type of license and serial number Period of us...

Страница 40: ...GigaSync must be connected to a network with Internet access In the current version of the system it is possible to change NTP servers from the SSH interface Cartridges CRT 1 CRT 2 and CRT 3 represent...

Страница 41: ...ff Information Description Name Modifiable according to your needs Status Depending on the condition it can be in On Off or Error Keys Type of GigaKey key inserted missing does not have GigaKey wrong...

Страница 42: ...th this source it will also be possible to have GPS positioning data coordinates and altitude and the number of satellites connected o SYNC IN RJ12 port to get the sync pulse from another device Sync...

Страница 43: ...the following link https filezilla project org To perform the software update procedure you must complete the following steps Download the 9dot update file that can be found at https 9dot it in the do...

Страница 44: ...entering the corresponding number and hitting enter A warning sign will appear asking us if we are sure we want to make the change ATTENTION Be careful to upload the correct package for your device I...

Страница 45: ...e www skylinkstelecoms ie VanCo U okol doven 9 143 00 Praha 12 Czech Republic 420 246 035 451 obchod vanco cz www vanco cz Wifidom Offices Calle Valencia 63 08015 Barcelona Spain Headquarters Avenida...

Страница 46: ...Union and the United Kingdom Copyright 2020 9dot GigaSync is a registered trademark of 9dot S r l in the European Union and the United Kingdom Copyright 2017 9dot All other registered and unregistere...

Отзывы: