240 | Aprisa LTE User Manual
GNSS Alarm Events
Event
Event Function
Event Type
Default
Severity
gnssActivity
Possible events:
Position set to the GNSS position
e.g. ‘
41.2362751, 174.8271497,
0M
’
When manually stored position is updated
Position fix lost (GPS Disabled)
Position fix acquired: GNSS position
For the first time position is detected after power on/gnss being
enabled entering/exiting geofenced area
Informational
gnssPositionAccuracy
Alarm active if GNSS signal HDOP is > 5
Alarm
Warning
gnssLOS
Alarm active if GNSS signal is lost.
Alarm will not show for first 60 seconds after GNSS is enabled.
When alarm is cleared, additional info should indicate the newly
discovered position.
Alarm
Minor
gnssOutsideGeofence
Alarm generated if user is outside the geofence radius specified by
the trigger max value of the alarm for the specified duration.
Alarm is cleared when geofence radius is less than the clear max
value of the alarm configuration.
Alarm
(Threshold
Type)
Warning