Alarm Events | 239
Aprisa LTE User Manual 2.1
5.
Alarm Events
Alarm Events
Event
Event Function
Event Type
Default
Severity
SMS Received
Only logged if authentication passes.
Contains details of received message
Info Event
SMS Authentication Failed
Message similar to “SMS From failed authentication”
Info Event
Component failure alarm
When cellular modem is not responding
Alarm
Critical
Sim card not found
This alarm is raised if a PDN profile is configured for a SIM card
that is not present.
Alarm shall not be raised for empty slot if it is not configured.
Alarm
Critical
Cell Not Registered on
Network
When cell network registration fails
Alarm
Major
Cellular Link Failure
When cellular link fails
Alarm
Major
Cellular on Roaming
When cellular goes on roaming
Alarm
Major
PIN failed
Raised when SIM card has rejected the configured PIN
Alarm
Major
PUK lock
Raised when SIM card has entered PUK lock state
Alarm
Major
Switch occurred
Text will indicate what PDN/Network has failed, and what is
becoming active
Info Event
PDN Profile Lock Active
Alarm
Warning
RSSI Alarm
When RSSI is lower or higher than configured thresholds
Alarm
Warning
RSRP Alarm
When RSRP is lower or higher than configured thresholds
Alarm
Warning
RSRQ Alarm
When RSRQ is lower or higher than configured thresholds
Alarm
Warning
SNR Alarm
When SNR is lower or higher than configured thresholds
Alarm
Warning
SINR Alarm
When SINR is lower or higher than configured thresholds
Alarm
Warning
Daily Usage Exceeded SIMx
When combined TX+RX byte count is exceeded for SIMx in current
day (rolling over at 0:00 each day)
Alarm
Warning
Weekly Usage Exceeded
SIMx
When combined TX+RX byte count is exceeded for SIMx in current
week (rolling over at 0:00 on monday)
Alarm
Warning
Monthly Usage Exceeded
SIMx
When combined TX+RX byte count is exceeded for SIMx in current
month (rolling over at 0:00 on configured month start day)
Alarm
Warning
RX Bytes SIMx
When RX bytes received on SIMx outside configured trigger
upper/lower in configured duration.
Alarm is cleared if values within clear upper/lower.
If max is 0 it is ignored
Alarm
Warning
RX Packets SIMx
When RX packets received on SIMx outside configured trigger
upper/lower in configurable duration.
Alarm is cleared if values within clear upper/lower.
If max is 0 it is ignored
Alarm
Warning
TX Bytes SIMx
When TX bytes sent on SIMx exceed configured trigger upper/lower
in configurable duration.
Alarm is cleared if values within clear upper/lower.
If max is 0 it is ignored
Alarm
Warning
TX Packets SIMx
When TX packets sent on SIMx exceed configured trigger
upper/lower in configurable duration.
Alarm is cleared if values within clear upper/lower
If max is 0 it is ignored
Alarm
Warning
No RX data
When no data is received during the configured period
Alarm
Warning
Содержание Aprisa LTE
Страница 1: ...User Manual February 2021 Version 2 1 released with software build 2 1 00811003 ...
Страница 2: ......
Страница 6: ...6 Aprisa LTE User Manual 2 1 Compliance Canada ISED future compliance ...
Страница 10: ......
Страница 110: ...110 Aprisa LTE User Manual ...
Страница 130: ...130 Aprisa LTE User Manual ...
Страница 149: ...Managing the LTE 149 Aprisa LTE User Manual 2 1 Services Services Summary ...
Страница 154: ...154 Aprisa LTE User Manual Controls Synchronize Now This Synchronize Now button provides manual Synchronization ...