196 | Aprisa LTE User Manual
Severity
The Severity parameter sets the alarm severity.
Severity
Function
Critical
The Critical severity level indicates that a service affecting condition has occurred and an
immediate corrective action is required. Such a severity can be reported, for example,
when a managed object becomes totally out of service and its capability must be restored.
Major
The Major severity level indicates that a service affecting condition has developed and an
urgent corrective action is required. Such a severity can be reported, for example, when
there is a severe degradation in the capability of the managed object and its full capability
must be restored.
Minor
The Minor severity level indicates the existence of a non-service affecting fault condition
and that corrective action should be taken in order to prevent a more serious (for
example, service affecting) fault.
Such a severity can be reported, for example, when the detected alarm condition is not
currently degrading the capacity of the managed object.
Warning
The Warning severity level indicates the detection of a potential or impending service
affecting fault, before any significant effects have been felt. Action should be taken to
further diagnose (if necessary) and correct the problem in order to prevent it from
becoming a more serious service affecting fault.
Information
No problem indicated
–
purely information
Suppress
This parameter determines if the action taken by an alarm.
Option
Function
None
Alarm triggers an event trap and is logged in the LTE
Traps
Alarm is logged in the LTE but does not trigger an event trap
Traps and Log
Alarm neither triggers an event trap nor is logged in the LTE
Lower Limit / Upper Limit
Threshold alarm events have lower and upper limit settings. The alarm is activated if the current reading is
outside the limits.
Example: 4 Temperature Threshold
The Lower Limit is -30 C and the Upper Limit is 75 C.
If the Temperature exceeds 75 C, the alarm will activate.
Units (1)
The Units parameter shows the unit for the Lower Limit and Upper Limit parameters.
Duration
This parameter determines the period to wait before an alarm is raised if no data is received.
Units (2)
This parameter shows the unit for the Duration parameters.
Содержание Aprisa LTE
Страница 1: ...User Manual February 2021 Version 2 1 released with software build 2 1 00811003 ...
Страница 2: ......
Страница 6: ...6 Aprisa LTE User Manual 2 1 Compliance Canada ISED future compliance ...
Страница 10: ......
Страница 110: ...110 Aprisa LTE User Manual ...
Страница 130: ...130 Aprisa LTE User Manual ...
Страница 149: ...Managing the LTE 149 Aprisa LTE User Manual 2 1 Services Services Summary ...
Страница 154: ...154 Aprisa LTE User Manual Controls Synchronize Now This Synchronize Now button provides manual Synchronization ...