Ten liters inside the tank
that cannot be removed
Fig. 61
The table
You add the first portion into the tank. The level must change from 115 to a different
value. If the level value doesn’t change, check the drainage holes of the sensor. They could
be blocked by an insulation tape you left there after the calibration at full and empty or
some surplus of the sealer got stuck in them.
If this happens, the air inside the tubes gets trapped and doesn’t allow the fuel go up
the tubes.