![3scort TD-BLE Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/3scort/td-ble/td-ble_user-manual_3190438032.webp)
Fig. 47
Selecting folder and creating a new file
Then you can select either
Filling
or
Draining
method (
Fig. 48
,
1
,
2
).
The filling
method is recommended because it tends to be more accurate
.
In case of the draining method you can never be 100% sure of what is the current
volume of the fuel inside the tank (
Fig. 49
) and if the tank is 100% full.
Next, give the table’s file a name (
Fig. 48
,
3
) and set the portion volume (
Fig. 48
,
4
).
ATTENTION! Portion volume is not the number of portions! It is the number of
liters/gallons each portion will be equal to!
In the example below the tank
supposedly contains 100 liters and that volume can be divided into 10 portions of 10
liters. If the tank had a total capacity of 300 liters and the idea was to calibrate it in 10
portions, the Portion volume would have been set as 30 liters.
Once finished with all that, press
Continue
(
Fig. 48
,
5
).
32
Содержание TD-BLE
Страница 3: ...TD BLE design Design of the 1st generation TD BLE 3...
Страница 4: ...Design of the 2nd generation TD BLE 4...
Страница 7: ...Fig 4 Sensor search Fig 5 Data received in Advertising mode 7...
Страница 28: ...Fig 41 Putting the sensor inside tank Fig 42 Fixing the self tapping screws 28...
Страница 40: ...Fig 62 Second portion is in Fig 63 The table with two portions You continue like that until the tank is full 40...
Страница 43: ...Fig 66 Tank filled Fig 67 Tank calibration table in the app and with all rows in a csv file 43...
Страница 71: ...Fig 103 Key screwed in the seal Fig 104 Extracting the seal 71...
Страница 73: ...Mounting dimensions Fig 106 Mounting dimensions 73...
Страница 74: ...How strong to tight up self tapping screws Fig 107 How strong to tight up self tapping screws 74...