![3scort TD-BLE Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/3scort/td-ble/td-ble_user-manual_3190438023.webp)
If the sensor cannot be installed in the geometric center of the tank, try to pick a spot
as close to the geometric center as possible; that spot also must coincide with the
point where the tank’s height is at its maximum. This way you
minimize the
magnitude of the oscillations
in the level readings caused by the fuel’s sloshing
during trips.
Why must the sensor be installed in the geometric center of the
tank?
The highest point must be selected
for the sensor to be able
to measure all the fuel
inside the tank
without any blind zones
.
The readings of the sensor installed in the center of the tank will be less affected by the
fuel sloshing than the readings of the sensor installed close to one of the tank’s walls.
If the sensor cannot be installed in the tank’s center, consider installing two sensors -
one at each end of the tank. Each sensor will compensate for the fuel surges and drops in
the readings of another.
Fig. 32
Position of the sensor and fuel sloshing
23
Содержание TD-BLE
Страница 3: ...TD BLE design Design of the 1st generation TD BLE 3...
Страница 4: ...Design of the 2nd generation TD BLE 4...
Страница 7: ...Fig 4 Sensor search Fig 5 Data received in Advertising mode 7...
Страница 28: ...Fig 41 Putting the sensor inside tank Fig 42 Fixing the self tapping screws 28...
Страница 40: ...Fig 62 Second portion is in Fig 63 The table with two portions You continue like that until the tank is full 40...
Страница 43: ...Fig 66 Tank filled Fig 67 Tank calibration table in the app and with all rows in a csv file 43...
Страница 71: ...Fig 103 Key screwed in the seal Fig 104 Extracting the seal 71...
Страница 73: ...Mounting dimensions Fig 106 Mounting dimensions 73...
Страница 74: ...How strong to tight up self tapping screws Fig 107 How strong to tight up self tapping screws 74...