When you calibrate the sensor, the current CNT value is saved as either the Full calibration
value (if you press the
Full
button) or as the Empty calibration value (if you press the
Empty
button).
Fig. 14
CNT and Full
before
pressing Full
Fig. 15
CNT and Full
after
pressing Full
How to and why calibrate sensors?
Initially, the sensor is calibrated at its original length.
Once you change it by cutting or
extending the tubes, you need to recalibrate it
i.e. to record the new CNT values that the sensor
calculates when its tubes are either full or empty.
13