5
78-8125-3042-2-B
Straight Splice
Basic Technique for Straight Splicing 3M
™
3M710 25-Pair Modules
1. Set group holders (fig. 1 #12) 38mm (1 1/2”)
above the position of the cable units to be spliced.
2. To disengage the “T” bar from the locked
position, turn the locking knob until the flat sec-
tion releases the “T” bar. (fig. 2 & 3 #4)
3. The “T” bar is now clear of the module assem-
bly area allowing module construction.
4. Insert an index strip between the vertical side
posts. (fig. 1 #2) The index strip cathedral win-
dows and latch locks should face the
operator/front.
5. Push the “L” clip knob inward to allow the
index strip to seat along the module assembly chan-
nel and locate under the spring loaded “L” clips
(fig. 1 # 8 & 9)
6. Secure the 25-pair group through the conductor
group holder. (fig. 1 #12) and dress individual pairs
into the cathedral windows of the index strip. Each
pair is divided by a colored peak projection. To
assist correct assembly, a color code guide (fig. 1
#10) is located on the operator side of the tool.
Note: The conductors must lay through the index strip straight and must not be pulled tight.