background image

Page 8

LIGHTFALLS by 3M™ + Todd Bracher Installation Guide - Sconce, Rev. C, Feb. 2014

Installation Guide                                            LIGHTFALLS by 3M™ + Todd Bracher
                                                                                                                        Sconce

Before Energizing the Circuit

Ensure that the cabling is secure, the connections are tight and the length of cable between the Lightfalls fixture and power unit is within the maximum 
for the gauge of wire used.

Component Replacement

The power unit may be serviced by an electrician. Replacement Lightfalls fixtures 
and accessory kits can be ordered from 3M. For ordering information for full mount-
ing kits, please see the Lightfalls by 3M + Todd Bracher Specification Sheet or go to 
www.3Marchitecturalmarkets.com.

Handling, Cleaning and Repairing

Handling

Handle the Lightfalls fixture with care. This assembly can be damaged if improperly or roughly handled. Keep the Product in its original packaging until 
installation, and if feasible, transport the Product to the site in its original box. 

Cleaning

If needed, use a mild, non-abrasive, water-based detergent solution to clean main reflectors. Plastic polishes may also be used. 

DO NOT

 use solvent-

based, ammonia-based cleaning solutions or glass cleaners. These may mar or discolor the transmissive lens. The flat secondary reflector plates may be 
cleaned with glass cleaner. This same recommendation applies to the non-reflector side (acrylic), however, this side can be repaired of light scratches 
using acrylic polishing compounds.

Repairing

Except for replacing the replaceable components, 

DO NOT

 attempt to repair the Lightfalls fixtures, which do not have user-serviceable parts.

Troubleshooting

If the solutions below do not work for you, please call 3M Technical Service at 1-888-650-3497.

Table D. Troubleshooting

Related Documentation

Please refer to the Lightfalls by 3M + Todd Bracher Specification Sheet for product specifications and ordering information.

Problem

Potential Cause 

What to Do

LED does not illumi-
nate

LED driver does not have 
AC input

Make sure light switch or other control relay is on and/or breaker is on.

Secondary side open circuit

Find and fix open connection. If the Output Voltage from the LED driver is 36V, but there is no light coming 
from the LED, there is likely an open circuit. Make sure connectors are properly seated.

Secondary side short circuit 
or reverse connection

Find and fix short circuit. If the Secondary LED wiring is shorted together or connected backwards, the LED 
driver should read near 0V. The connector at the fixture can be forced in backwards. Make sure the connector 
is in the keyed orientation.

LED driver does not have 
>30 V DC output

If input AC is supplied but DC output voltage is not supplied, the LED driver needs to be replaced. Remove load 
before measuring LED driver output, because a short on the secondary side can make the LED driver seem 
broken.

LED driver 0–10V control 
wiring shorted

Find and fix short.

LED does not dim

Control wiring open

Find and fix open.

Light does not illumi-
nate full fixture

A primary reflector is mis-
oriented by 90 degrees

Check all primary reflectors for correct orientation.

Table C. Replaceable Components

Replacement Parts

Order Code

LED heatsink assembly, linear

LF-HSL-XX-XX

LED Driver

LF-PSU

Содержание LIGHTFALLS

Страница 1: ... Product falling The Lightfalls fixture can weigh up to 1 pounds 0 5 kilograms Ensure that mounting brackets are adequately fastened to the load bearing point and able to carry the required load Always refer installation to a licensed electrician or certified lighting contractor DO NOT use the Product if it has incurred any physical damage Refer to a licensed electrician to check the Product befor...

Страница 2: ...h this product vary by order Refer to your packaging slip for detailed information on the exact quantities provided Additional Materials The materials listed as required are required at a minimum Some sites may require additional materials not listed based on their installation Required Metal enclosure minimum dimensions 4 Gang Electrical Masonry Box 7 41 x 3 75 x 3 5 188 21mm x 95 25mm x 88 9mm o...

Страница 3: ...ss light out of the fixture Table A Maximum Run Length Between LED Driver and Junction Box Plan Power Unit Placement and Cable Routing Select a location for the power unit satisfying local ordinances Determine how the cables will be routed through wall or ceiling For fixture to power unit distance greater than 25 feet Supply additional secondary wire Figure 1 Page 4 between the junction box and th...

Страница 4: ...ed location For ceiling mounts mount the junction box above the power drop A cosmetic junction box cover is customer supplied Use provided harness to connect to LED assembly LED Assembly Plug Recpt LED Assembly Plug Recpt AC_L AC_N To additional supplies on same dimmer switch To additional supplies on same dimmer switch Dimmer Relay such as Lutron PP 120H or PP 277H depending on installation Dim D...

Страница 5: ... one suggested ori entation 1 Choose the location and orientation for the Lightfalls Sconce 2 Mark the positions for the sconce bracket anchor point screw locations 3 Mark the position for the thick panel bushing location for wire routing 4 Install drywall concrete anchors as applicable and the thick panel bushing See Figure 2 5 Install the Sconce Bracket to the anchor points with customer supplie...

Страница 6: ...once Installing the Product cont 6 Connect each Wire Harness to the Heatsink LED Assembly and route wire harness through bushing See Figure 4 7 Position both Heatsink LED Assemblies at the Sconce Bracket as shown Figure 5 Heatsink LED Figure 4 Wire Harness Connection Wire Harness Connector Figure 5 Heatsink LED Assembly Position ...

Страница 7: ...igure 7 with the high sides of the reflector aligned with the Heatsink LED assemblies NOTE The reflective surface can be easily damaged Take care not to scrape the tips of the metal standoff against the inside sur face of the primary reflector Press with enough force to snap the reflector into place on the reflector standoff To produce a different lighting effect re install the reflector rotated b...

Страница 8: ...t to repair the Lightfalls fixtures which do not have user serviceable parts Troubleshooting If the solutions below do not work for you please call 3M Technical Service at 1 888 650 3497 Table D Troubleshooting Related Documentation Please refer to the Lightfalls by 3M Todd Bracher Specification Sheet for product specifications and ordering information Problem Potential Cause What to Do LED does n...

Страница 9: ... under the 3M Warranty as to Product that has been a modified or altered in any manner b damaged through contact with a person or thing misuse accident vandalism neglect or other action by anyone other than 3M c affected by environmental conditions such as power fluctuations improper LED driver or activity by animals or insects or d used not in compliance with all applicable standards and electric...

Отзывы: