Page 2
LIGHTFALLS by 3M™ + Todd Bracher Installation Guide - Sconce, Rev. C, Feb. 2014
Installation Guide LIGHTFALLS by 3M™ + Todd Bracher
Sconce
General Information
Make sure each installer reads this Installation Guide before beginning. Give these instructions to the customer upon completion. Call 3M at 1-888-650-
3497 for questions about the Product.
Read Before Installing
Be sure you have the most current Installation Guide. The information in this Installation Guide is subject to change. Call 3M at the above number, or go
to www.3MArchitecturalMarkets.com/Lighting to obtain a current Installation Guide. The site should be inspected to ensure it has been adequately pre-
pared for installation.
Supplied Components
(Not to Scale)
Component quantities supplied with this product vary by order. Refer to your packaging slip for detailed information on the exact quantities provided.
Additional Materials
The materials listed as required are required at a minimum. Some sites may require additional materials not listed based on their installation.
Required
•
Metal enclosure, minimum dimensions: 4-Gang Electrical Masonry Box
7.41" x 3.75" x 3.5" (188.21mm x 95.25mm x 88.9mm) or 90 cu. in. for
each LED driver
•
Primary wire (AC)
•
Wire nuts
Optional
•
Junction box (see Figure 1, Page 4)
•
Additional secondary wire (DC)
•
Conduit for secondary wire (if in plenum or riser)
•
Gang box for dimmer switch
•
Dimmer control wiring (recommend purple and gray) — minimum 22
AWG
•
Dimmer switch (such as Lutron DVTV)
•
Dimmer relay (such as Lutron PP-120H)
6–32 x 3/4"
Hex Screw
#6 Hex Driver
#6 Screw Cap
Primary Reflector Standoff
Heatsink/
LED Assembly
16W LED Driver, Dimmable
Primary Reflector
Sconce Bracket
25 ft. Wire Harness with Connector
Thick Panel Bushing
(Heyco 3119)