Installation Overview

The Product is an optical system that operates through precisely designed light reflections. Be careful not to bend the components when assembling and installing 
the Product. Installation includes the following steps:

Plan location

Select power unit enclosure

Plan power unit placement and cable routing

Rough in cable

Install power unit

Install junction box (optional)

Assemble and install the Lightfalls fixture

Orient and mount primary reflector

Installing the Product

To reduce risk associated

with fire: 

Only use the LED

driver(s) provided by 3M.

!

WARNING

Plan Location

Identify the proposed location on wall or ceiling.

Select Power Unit Enclosure

Local ordinances require an electrical enclosure for the LED drivers. The size and 
type of enclosure will depend upon where it is to be installed.

Select a suitable metal enclosure, minimum dimensions 7.41" x 3.75" x 3.5" 
(188.21mm x 95.25mm x 88.9mm) or 90 cu. in. for each LED driver.

Mount the LED driver in the metal enclosure.

NOTE:  The LED driver has a maximum case temperature of 70°C (158°F) 
and begins derating 20%/10°C at 50°C. Undersizing the enclosure or 
mounting the LED driver with poor thermal contact may result in decreased 
LED driver lifetime and void the warranty. If the LED driver case tempera-
ture is 70°C, there will be approximately 40% less light out of the fixture.

Table A. Maximum Run Length Between LED Driver and Junction Box

Plan Power Unit Placement and Cable Routing

Select a location for the power unit satisfying local ordinances.

Determine how the cables will be routed through wall or ceiling. 

For fixture to power unit distance greater than 25 feet:

Supply additional secondary wire (Figure 1, Page 4) between the junction box 
and the LED driver.

Determine the run length between the power unit and the junction box.

Select the appropriate wire gauge for additional secondary wire between the 
LED driver and junction box using Table A. Column 3 of Table A displays the 
maximum run lengths with a shortened wire harness less than or equal to 5 
feet. One reason to shorten the wire harness would be to run plenum-rated 
or riser-rated cable instead.

The Product operates on a 

Class 2 circuit 

and must be wired as in Figure 1 (Page 

4).

IMPORTANT NOTE:  To operate correctly, the wire distance from the LED 
driver to the Lightfalls fixture must be within the maximum run length indi-
cated in Table A between LED driver and junction box.

Rough in Cable

Rough in the cable as shown in the diagram in Figure 1 (Page 4).

For installations without a dimmer and relay:

Cap off 

Dim+

 and 

Dim–

 with wire nuts and connect 

AC_L

 directly to 

ACL

 and 

AC_N

 directly to 

ACN

 on the LED driver.

Table B. DC Power Requirements (Varies Depending on Configuration)

Wire Gauge (AWG)

Distance with
25 ft. harness

Distance with harness
cut to 5 ft. or less

12

70

100

14

45

100

16

28

70

18

18

45

20

12

28

Model 

Description 

Max Input
Current (A)

Typical Input
Power (W)

Typical Input
Voltage (V)

LF1-XX

2 LEDs, each at half 
power

0.45

16.2

36

Содержание LIGHTFALLS

Страница 1: ... Product falling The Lightfalls fixture can weigh up to 1 pounds 0 5 kilograms Ensure that mounting brackets are adequately fastened to the load bearing point and able to carry the required load Always refer installation to a licensed electrician or certified lighting contractor DO NOT use the Product if it has incurred any physical damage Refer to a licensed electrician to check the Product befor...

Страница 2: ...h this product vary by order Refer to your packaging slip for detailed information on the exact quantities provided Additional Materials The materials listed as required are required at a minimum Some sites may require additional materials not listed based on their installation Required Metal enclosure minimum dimensions 4 Gang Electrical Masonry Box 7 41 x 3 75 x 3 5 188 21mm x 95 25mm x 88 9mm o...

Страница 3: ...ss light out of the fixture Table A Maximum Run Length Between LED Driver and Junction Box Plan Power Unit Placement and Cable Routing Select a location for the power unit satisfying local ordinances Determine how the cables will be routed through wall or ceiling For fixture to power unit distance greater than 25 feet Supply additional secondary wire Figure 1 Page 4 between the junction box and th...

Страница 4: ...ed location For ceiling mounts mount the junction box above the power drop A cosmetic junction box cover is customer supplied Use provided harness to connect to LED assembly LED Assembly Plug Recpt LED Assembly Plug Recpt AC_L AC_N To additional supplies on same dimmer switch To additional supplies on same dimmer switch Dimmer Relay such as Lutron PP 120H or PP 277H depending on installation Dim D...

Страница 5: ... one suggested ori entation 1 Choose the location and orientation for the Lightfalls Sconce 2 Mark the positions for the sconce bracket anchor point screw locations 3 Mark the position for the thick panel bushing location for wire routing 4 Install drywall concrete anchors as applicable and the thick panel bushing See Figure 2 5 Install the Sconce Bracket to the anchor points with customer supplie...

Страница 6: ...once Installing the Product cont 6 Connect each Wire Harness to the Heatsink LED Assembly and route wire harness through bushing See Figure 4 7 Position both Heatsink LED Assemblies at the Sconce Bracket as shown Figure 5 Heatsink LED Figure 4 Wire Harness Connection Wire Harness Connector Figure 5 Heatsink LED Assembly Position ...

Страница 7: ...igure 7 with the high sides of the reflector aligned with the Heatsink LED assemblies NOTE The reflective surface can be easily damaged Take care not to scrape the tips of the metal standoff against the inside sur face of the primary reflector Press with enough force to snap the reflector into place on the reflector standoff To produce a different lighting effect re install the reflector rotated b...

Страница 8: ...t to repair the Lightfalls fixtures which do not have user serviceable parts Troubleshooting If the solutions below do not work for you please call 3M Technical Service at 1 888 650 3497 Table D Troubleshooting Related Documentation Please refer to the Lightfalls by 3M Todd Bracher Specification Sheet for product specifications and ordering information Problem Potential Cause What to Do LED does n...

Страница 9: ... under the 3M Warranty as to Product that has been a modified or altered in any manner b damaged through contact with a person or thing misuse accident vandalism neglect or other action by anyone other than 3M c affected by environmental conditions such as power fluctuations improper LED driver or activity by animals or insects or d used not in compliance with all applicable standards and electric...

Отзывы: