5
78-8140-2401-0-B
4.0 For Armored Cables Only
4.1
The following two grounding kits are available:
3M
™
Internal Ground Kit
ECAM-GND-6-AWG
80-6113-1702-7
3M
™
Internal Ground Kit
ECAM-GND-14-AWG
80-6113-1704-3
4.2
Prepare cable as describe in the previous
armored cable prep section Wrap the sheath
with Scotch
®
All Weather Telephone Vinyl
Plastic Tape 88T or equivalent to protect fiber
from the sharp cable sheath edges. Do not wrap
the last inch (25 mm) of the cable sheath.
4.3
Prepare the closure base by locating the ground
studs inside the closure base. Loosen the upper
nut 3 to 4 turns on the ground stud using a 1/2
inch (13mm) nut driver. It is not necessary to
remove the small vinyl caps.
4.4
Place the forked end of the ground wire between
the pair of washers. Re-torque the ground stud
nut to 30 in-lbs.