Specifications
Section 3
Page 74
Note:
1
See figures next page for accuracies. All resistance to
fault
measurement accuracies have an added factor of
(2 x 10
-8
) RF ohms.
2
Single pair hookup
measurement accuracy is strictly
dependent on whether the reference pair is exactly the
same electrical length as the faulted pair. Accuracies are
doubled for single pair hookup.
3
Accuracy depends on correct temperature setting as well
as gauge accuracy of copper. The temperature can be
read by the built-in sensor or can be operator-entered.
2 –
-
-
-
-
1.5
–
-
-
-
-
1 –
-
-
-
-
.5 –
-
-
-
-
0 –
Accuracy in ohms for Various Fault Resistances
Maximum
Error in
ohms
Resistance to Strap in ohms
2
10
20
40
4
20 Mohms
10 Mohms
<1 Mohm
30 Mohms
100
400
1000
200
1
0
5
10
15
20
25
30
35
40
0
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
30 Mohms
20 Mohms
10 Mohms
< 1 Mohm