21
Electromagnetic Field Sensor, Power Density Meter and Effective
Isotropically Radiated Power (EIRP) Meter Display and Controls
MENU FUNCTION
When the MENU F button is pressed momentarily, the INTERVAL
and AVERAGE data recording timing can be configured.
INTERVAL, in seconds, is the sampling time for PEAK data to be
recorded onto the microSD
™
storage card.
AVERAGE, in seconds, is the sampling time for AVERAGE data to
be recorded onto the microSD storage card.
At the HARDWARE SETUP menu, press the triangle (MODE
OPTION) button located at the upper right side of the display.
The MODES OPTION screen is used to enable or disable any of
the functions modes: 1) EM field; 2) Power Density; and 3) EIRP.
You can always enable previously disabled modes.
Use the navigation bar as follows:
UP/DOWN scrolls the cursor field through the three modes.
LEFT/RIGHT enables or disables the selected mode.
“V” – enabled; “X” – disabled
When the MENU F button is pressed for a longer period, the hardware setup is shown. At
this point, brightness, off-time and antenna factor can be adjusted.
Relative Antenna Factor (AF)
-40 dBm-1 to 40 dBm-1
Default relative antenna factor for the supplied local antenna is 0.