50
C
HAPTER
5: P
OWER
-O
N
on the left side of the LED panel. Table 9 shows the correlation between
the current system state and SYS LEDs display. For example, during
normal operation the PWR LED is on, the FAIL LED is off and the ACT LED
is flashing. The LEDs on the right side of the panel indicate the status of
the Ethernet port, the Service port and the Control port.
Figure 9
Switching Module LEDs
The following table also provides information about the LED display of
system states but is organized by system status LED.
Control
1 0 B A S E - T
Status
S e r v i c e
Status
Status
P W R
A C T
F A I L
Table 9
CoreBuilder System States
System State
Power
(green)
Fail
(red)
Activity
(yellow)
10BASE-T
Status
(green)
Service Port
Status
(green)
Control
Terminal Status
(green)
Power-on
On
Off
On
On
Flashing
Flashing
Normal operation
On
Off
Flashing
On
On
On
Hardware fault
On
On
Off
Off
Off
Off
Software fault
On
Off
Not flashing Undetermined Undetermined Undetermined
No power to unit
Off
Off
Off
Off
Off
Off
Table 10
Description of Switching Module LEDs
LED
Color
Description
Source
PWR (Power)
Green
DC power input active.
Hardware
ACT (Activity)
Yellow
Should blink continuously when
operational.
Software
FAIL
Red
CPU failure.
Hardware
CPU or
Watchdog
10BASE-T
STATUS
Green
10BASE-T link OK. The Ethernet link is
active.
Hardware
Ethernet
controller
Содержание CoreBuilder 7000
Страница 8: ......
Страница 20: ...20 CHAPTER 1 OVERVIEW...
Страница 54: ...54 CHAPTER 5 POWER ON...
Страница 96: ...96 CHAPTER 8 TROUBLESHOOTING...
Страница 100: ...100 APPENDIX A ATM SWITCH FA 24 CELL SWITCHING MODULE SPECIFICATIONS...
Страница 104: ...104 APPENDIX B SAFETY INFORMATION...
Страница 122: ...122 APPENDIX D CABLING REQUIREMENTS...
Страница 128: ...128 APPENDIX E TECHNICAL SUPPORT...
Страница 148: ...148 INDEX...