MESSAGE
CAUSE
SOLUTION
ALARM 8
Piston pressure
sensor output
lower than
minimum
Piston Pressure sensor faulty.
Lack of continuity in wiring
Moisture in connector.
Sensor broken or disconnected
Check for15vdc supply
Check for output 0.5 vdc
Check for moisture or fluid.
Check connector and wiring
•
Replace Transducer if faulty
ALARM 9
Piston pressure
sensor output
higher than
maximum
Piston Pressure sensor faulty.
Lack of continuity in wiring
Moisture in connector.
Sensor broken or disconnected
Check for15vdc supply
Check for output 0.5 vdc
Check for moisture or fluid.
Check connector and wiring
•
Replace Transducer if faulty
ALARM 10
Rod pressure
sensor output
lower than
minimum
Rod Pressure sensor faulty.
Lack of continuity in wiring
Moisture in connector.
Sensor broken or disconnected
Check for15vdc supply
Check for output 0.5 vdc
Check for moisture or fluid.
Check connector and wiring
•
Replace Transducer if faulty
ALARM 11
Rod pressure
sensor output
higher than
maximum
Rod Pressure sensor faulty.
Lack of continuity in wiring
Moisture in connector.
Sensor broken or disconnected
Check for15vdc supply
Check for output 5.5 vdc
Check for moisture or fluid.
Check connector and wiring
•
Replace Transducer if faulty
ALARM 16
Shutoff output
fault.
Lack of continuity in wiring
Fault internal SLIM
Shutoff solenoid
Check for12vdc supply
Check connector and wiring
ALARM 22
Internal WDO
fault
Faulty display
Check wiring of display
and harness
ALARM 41
CRC Error
EPROM SW
Internal fault SLIM display
Cycle power on SLIM display
Call Service
ALARM 42
CRC Error in
program
Internal fault SLIM display
Cycle power on SLIM display
Call Service
ALARM 43
CRC Error in
Load chart
ALARM 50
Cable reel
CANBUS
Internal fault SLIM display
Faulty wiring from display to cable
reel
Cycle power on SLIM display
Call Service
Check wiring and CAN line for
120 ohm resistor.
3B6
Troubleshooting Manual
Alarm/Fault codes
9